5-52
WR903 FP0R
Relay No. Name Description
R9030 Not used
R9031 Not used
R9032
COM port
communication mode
flag
- Turns on when the general-purpose communication function
is being used
- Goes off when the MEWTOCOL-COM or the PLC link
function is being used.
R9033
Print instruction
execution flag
Off: Printing is not executed.
On: Execution is in progress.
R9034
RUN overwrite
complete flag
Goes on for ony the first scan following completion of a rewrite
during the RUN operation.
R9035 Not used
R9036 Not used
R9037
COM port
communication error
flag
- Goes on is a transmission error occurs during data
communication.
- Goes off when a request is made to send data, using the
F159 (MTRN) instruction.
R9038
COM port reception
done flag during
general purpose
communication
- Turns on when the terminator is received during general -
purpose serial communication.
R9039
COM port
transmission done
flag during general-
purpose serial
communication
- Goes on when transmission has been completed in general-
purpose serial communication.
- Goes off when transmission is requested in general-purpose
serial communication.
R903A Not used
R903B Not used
R903C Not used
R903D Not used
R903E
TOOL port reception
done flag during
general purpose
communication
- Turns on the terminator is received during general -purpose
serial communication.
R903F
TOOL port
transmission done
flag during general-
purpose serial
communication
- Goes on when transmission has been completed in general-
purpose serial communication.
- Goes off when transmission is requested in general-purpose
serial communication.
A: Available, N/A: Not available
Note) R9030 to R9030F can be changed during 1 scan.