5-146
FP-X (A: Available, N/A: Not available)
Address Name Description
Read-
ing
Writ-
ing
DT90320 Lower words A
A
Note1)
DT90321
Elapsed
value
area
Higher words
Counting area for input (X5) of
the main unit.
A
A
Note1)
DT90322 Lower words A
A
Note1)
DT90323
Target
value
area
Higher words
HSC-CH5
The target value is set when
instructions F166 (HC1S) and
F167 (HC1R) are executed.
A
A
Note1)
DT90324 Lower words A
A
Note1)
DT90325
Elapsed
value
area
Higher words
Counting area for input (X6) or
(X6, X7) of the main unit.
A
A
Note1)
DT90326 Lower words A
A
Note1)
DT90327
Target
value
area
Higher words
HSC-CH6
The target value is set when
instructions F166 (HC1S) and
F167 (HC1R) are executed.
A
A
Note1)
DT90328 Lower words A
A
Note1)
DT90329
Elapsed
value
area
Higher words
Counting area for input (X7) of
the main unit.
A
A
Note1)
DT90330 Lower words A
A
Note1)
DT90331
Target
value
area
Higher words
HSC-CH7
The target value is set when
instructions F166 (HC1S) and
F167 (HC1R) are executed.
A
A
Note1)
DT90332 Lower words A
A
Note1)
DT90333
Elapsed
value
area
Higher words
Counting area for input (X0) or
(X0, X1) of the main unit.
A
A
Note1)
DT90334 Lower words A
A
Note1)
DT90335
Target
value
area
Higher words
HSC-CH8
Note2)
The target value is set when
instructions F166 (HC1S) and
F167 (HC1R) are executed.
A
A
Note1)
Note1) Writing in the elapsed value area is available by F1 (DMV) instruction only.
Writing in the target value area is available by F166 (HC1S) and F167 (HC1R) instructions only.
Note2) Available for the FP-X Ry type only.