Basic Instructions
2 − 119
Outline This changes the communication conditions for the COM port or Tool
port based on the contents specified by the character constant.
Program example
WX WY WR WL SV EV DT LD FL I K H M
modifier
S N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A A N/A
Explanation of example
When R0 turns on, the transmission format and baud rate for the COM. 1 port are set as follows.
Character bit: 8, Parity: Odd
Stop bit: 1
Baud rate: 19,200 bps
Description
The communication conditions for the port specified by No. 1 keyword are changed to the contents specified
by No. 2 keyword.
Contents that can be changed include the following:
1) Communication format
2) Baud rate
3) Unit No. For FP0R, indirect settings are available.
4) Header and Terminator
5) RS (Request to Send) control
FPΣ/FP−X/FP0R
SYS1
Availability
FPΣ/FP−X/FP0R
Communication conditions setting
A: Available
N/A: Not Available