Basic Instructions
2 120
Keyword setting
1) Communication format (Shared by the Tool, COM. 1 and COM. 2 ports)
Character bit
B7: 7bits B8: 8bits
Port used
TOOL: Tool port
COM1: COM. 1 port
COM2: COM. 2 port
Parity
PN: None PO: Odd PE: Even
Stop bit
S1: 1 S2: 2
SYS1, M TOOL,B7 PN S1
2) Baud rate (Shared by the Tool, COM. 1 and COM. 2 ports)
Port used
TOOL: Tool port
COM1: COM. 1 port
COM2: COM. 2 port
Baud rate
300: 300 bps 600: 600 bps
1200:1200 bps 2400: 2,400 bps
4800: 4,800 bps 9600: 9,600 bps
19200: 19,200 bps 38400: 38,400 bps
57600: 57,600 bps 115200: 115,200 bps
SYS1, M TOOL,19200
The baud rates of 300, 600 or 1200 bps can be specified only with the FP0R, FPX ver 2.0 or later and FPΣ ver3.10 or later.
Also, those baud rates cannot be specified by the system register.
3) Unit No. (Shared by the Tool, COM. 1 and COM. 2 ports)
Port used
TOOL: Tool port
COM1: COM. 1 port
COM2: COM. 2 port
Unit No.
No1 to No99: No. 1 to No. 99
SYS1, M TOOL,No1
For FP0R, the indirect settings of unit number is available.
Port used
TOOL: Tool port
COM1: COM. port
DT number that Unit No. is stored.
SYS1, M COM1, D000D
D000D = DT0
D9999 = DT9999
Always specify with a number of D+4 digits.
FPΣ/FPX/FP0R