Basic Instructions
2 122
Flag conditions
Error flag (R9007): Turns on and stays on when:
Error flag (R9008): Turns on for an instant when:
Any character other than a keyword is specified
There is no comma between No. 1 and No. 2 keywords
The small letter of the alphabet is used to specify the keyword (except for
numbers used to specify unit No.)
No communication cassette has been installed when COM1 or COM2 has
been set
The setting of the unit No. setting switch is anything other than 0 when
COM1 or COM2 has been set and the unit No. is being changed
The unit No. set using this instruction is anything other than a value
between 1 and 99
The baud rate or transmission format for COM1 has been changed when
the PLC link mode is specified for COM1
The baud rate or transmission format is changed while the Tool port, COM.
port 1, or COM. port 2 is being initialized using MODEM
The communication mode is set to anything other than the general
communication mode when header and terminator have been set
Any communication cassette other than the 1channel RS232C type
communication cassette is installed when using RS control
The specified unit No. is larger than the largest unit No. specified by the
system register when the COM. 1 port is in the PLC link mode
FPΣ/FPX/FP0R