High−level Instructions
3 − 339
Outline Sends specified data to another PLC or computer from the serial port of
the unit.
Program example
Ladder
Diagram
Boolean
Ladder Diagram
Address Instruction
10
F145 SEND, DT10 , DT20 , DT 0 , K 100
S1
S2
Trigger
R0
D
N
10
11
ST R 0
F145 (SEND)
DT 10
DT 20
DT 0
K 100
S1 Starting 16−bit area for storing control data
S2 Starting 16−bit area for storing source data (data area at the local unit)
D 16−bit area of destination to send (The device No. is fixed at 0).
N Starting 16−bit address of the destination to send.
Operands
O
p
erand
Relay Timer/Counter Register
Index
register
SWR SDT
Constant
Index
modifier
Operand
WX WY WR WL SV EV DT LD In (*1)
SWR
SDT
K H
modifier
S1 A A A A A A A A N/A A A N/A N/A A
S2 A A A A A A A A N/A A A N/A N/A A
D N/A A A N/A N/A N/A A N/A N/A N/A N/A N/A N/A N/A
N N/A
A
(*2)
A
(*2)
A
(*2)
A
(*2)
A
(*2)
A
(*2)
A
(*2)
N/A N/A N/A A A A
(*1) I0 to ID
(*2) It can be specified only for the FP0R, FPΣ V3.20 or later, FP−X V2.50 or later, however, an operation error will occur
not a syntac error if K or H constant is specified as S1 and D.
Operation
It is used to send commands to the serial port (COM1 or COM2) of the specified unit in the MODBUS
mode connecting the unit that enables to receive the MODBUS command. (MODBUS command 05,
06, 15 and 16)
The data of the local area specfied by [S2] is written in the area of the remote unit specified by [D] and
[N], according to the specification for the 2−word data stored in the control data with starting area
specified by [S1].
FPΣ/FP−X/FP0R
F145
P145
(PSEND)
(SEND)
Data send
(For MODBUS master mode)
Availability
FP0R/FP−X
FPΣ: 32k
A: Available
N/A: Not Available