High−level Instructions
3 − 414
Explanation of example
Adds the time data stored in data registers DT11 and DT10 to the clock/calendar data stored in special data
registers DT9054 to DT9056 (DT90054 to DT90056) when trigger R0 turns on. The result is stored in data
registers DT32, DT31, and DT30.
92061710
DT9056 (DT90056) DT9055 (DT90055)
3024
DT9054 (DT90054)
Years Months Days Hours Minutes Seconds
June 17, 1992 10: 30’ 24”: H920617103024 (BCD)
+
0020
DT11
4500
DT10
Hours Minutes Seconds
20: 45’ 00”: H00204500 (BCD)
92061807
DT32 DT31
1524
DT30
Years Months Days Hours Minutes Seconds
June 18, 1992 7: 15’ 24”: H920618071524 (BCD)
(Addition)
Description
The date/clock data (3 words) specified by S1 and the time data (2 words) specified by S2 are added together.
The result (time of elapsed value) is stored in the area (3 words) specified by D.
BCD H code
S1+2 S1+1 S1
Years Months Days Hours Minutes Seconds
Date/clock data
+
BCD H code
S2+1 S2
Hours Minutes Seconds
Time data
BCD H code
D+2 D+1 D
Years Months Days Hours Minutes Seconds
Date/clock data
H00 to H99 H01 to H31 H00 to H59 H00 to H59
H00 to H99 H01 to H12 H01 to H31 H00 to H23 H00 to H59 H00 to H59
H0000 to H9999
H00 to H59 H00 to H59
(Addition)
H01 to H12 H00 to H23