High−level Instructions
3 − 424
Preparation for reception
Setting of COM 1 port reception buffer No. 416 and No. 417
The area of data registers DT0 up to DT2047 is the default reception buffer.
The maximum number of bytes that can be received is 4094 bytes.
No. of received
bytes
Reception
data
storage
area
Specified number of
words for No. 417
Specify start area as
No. 416.
Setting of COM 2 port reception buffer No. 418 and No. 419
(This setting is not available for the FP0R.)
The area of data registers DT2048 up to DT4095 is the default reception buffer.
The maximum number of bytes that can be received is 4094 bytes.
No. of received
bytes
Reception
data
storage
area
Specified number of
words for No. 419
Specify start area as
No. 418.
Setting of Tool port reception buffer No. 420 and No. 421
The area of data registers DT4096 up to DT6143 is the default reception buffer.
The maximum number of bytes that can be received is 4094 bytes.
No. of received
bytes
Reception
data
storage
area
Specified number of
words for No. 421
Specify start area as
No. 420.