High−level Instructions
3 − 591
Outline The specified number of seconds is changed into time data (a date and
time).
With FP2/FP2SH, this function is available from Ver. 1.50 or later.
Program example
Ladder
Diagram
Boolean
Ladder Diagram
Address Instruction
10
F231SECTM,DT0,DT10
S
Trigger
R0
D
10
11
ST R 10
F231 (SECTM)
DT 0
DT 10
S Area in which the number of seconds stored (32 bits)
D Head area in which time data stored
Operands
O
p
erand
Relay Timer/Counter Register
Index
register
Constant
Index
modifier
Operand
WX WY WR WL SV EV DT LD FL I K H f
modifier
S A A A A A A A A A A N/A N/A N/A A
D N/A A A A A A A A A A N/A N/A N/A A
Explanation of example
When the internal relay (R0) is on, the number of seconds for the data registers DT0 and DT1 is converted to
the time data based on the standard time, and stored in DT10 to 12.
H51
H03
(higher)
ex.)
H02
H06
H15
H12
DT0
DT1
H039D0A6A
(Binary value)
(lower)
(Dec.3,02 − 15:51:06)
(2002)
(60,623,466秒)
DT10
DT11
DT12
H59
H31
DT0
DT1
(higher)
ex.)
H00
H59
H23
H12
HBC19137F
(Binary value)
(lower)
(Dec.31,00 − 23:59:59)
(2100)
(3,155,759,999 seconds)
DT10
DT11
DT12
FP2/FP2SH/FP−X
F231
P231
(PSECTM)
(SECTM)
Second time data conversion
Availability
FP2/FP2SH/FP−X
FPΣ 32k/FP0R
A: Available
N/A: Not Available