High−level Instructions
3 − 592
Description
1) The input number of seconds (S) is converted to the time data based on standard time *1, and stored in
(D).
2) The conversion is in consideration of the leap year.
1 minute −−− 60 seconds
1 hour −−− 60 minutes
1 day −−− 24 hours
1 year (leap year) −−− 366 days
1 year (except a leap year) −−− 365 days
A leap year (4 multiple years) −−− Feb.29
3) The range which can specify the number of seconds (S) is 100 years which can be expressed by time
data.
H00000000 − HBC19137F −−− Normal conversion
HBC191380 − HFFFFFFFF −−− Conversion error
*1: Standard time is 00:00’00” on January 1, ’01.
D:
D+1:
D+2:
Minutes (H00−H59)
Days (H01−H31)
(higher)
Time data (D) (BCD)
Years (H00−H99)
S:
S+1:
Seconds data
(H00000000 − HBC19137F)
(lower)
Seconds (H00−H59)
Hours (H00−H23)
Months (H01−H12)
Second data (S)
(higher)
(lower)
Total Second Conversion
Second data (S)
Time data (D)
H00000000 ’01/01/01 00:00:00
H00000001 ’01/01/01 00:00:01
: :
H0000003C ’01/01/01 00:01:00
: :
H00000E10 ’01/01/01 01:00:00
: :
H00015180 ’01/01/02 00:00:00
: :
HBA368E7F ’99/12/31 23:59:59
HBA368E80 ’00/01/01 00:00:00
: :
HBC19137F ’00/12/31 23:59:59
Flag conditions
ΣError flag (R9007) (R9008):
− It turns on, when the specified address using the index modifier exceeds a limit.
− It turns on, when the number of seconds (S) is (S) >=HBC191380.
− It turns on, when the data memory of [D] exceeds the area.
2001
:
:
:
:
:
:
:
:
2099
:
:
2100