High−level Instructions
3 − 629
Outline These instructions retrieve a character string consisting of a specified
number of characters from the specified position in the character string.
With the FP0R/FPΣ/FP−X, the differential execution type instruction P263 (PMIDR)
cannot be specified.
Program example
Boolean
Ladder Diagram
Address Instruction
10
F263 MIDR, DT0,K1,K3,DT20
S1
Trigger
R10
S2
DS3
10
11
ST R 10
F263 (MIDR)
DT 0
K1
K3
DT 20
S1 Character string
S2 Area in which the character string position is stored, or constant data
S3 Area in which the number of characters is stored, or constant data
D Area in which the character string is stored
Operands
Relay Timer/Counter Register
Index
register
Constant
Inde
Operand
WX WY WR WL SV EV DT LD
FL
(*1)
I
(*2)
K H f M
modifier
S1 A A A A A A A A A A N/A N/A N/A N/A A
S2 A A A A A A A A A A A A N/A N/A A
S3 A A A A A A A A A A A A N/A N/A A
D N/A A A A A A A A A A N/A N/A N/A N/A A
(*1) Cannot be specified with FP0R, FPΣ and FP−X.
(*2) I0 to ID
F263
P263
(PMIDR)
(MIDR)
Retrieving a character string from a character string
A: Available
N/A: Not Available