High−level Instructions
3 − 661
Outline This instruction carries out dead-band control for 16-bit data.
For the FP0R/FPΣ/FP−X, the P type high−level instruction “P287
(PBAND)” is not available.
Program example
Boolean
Ladder Diagram
Address Instruction
S1
Trigger
S3S2 D
F287 BAND, DT10, DT20, DT30, DT4010
R0
10
11
ST R 0
F287 (BAND)
DT 10
DT 20
DT 30
DT 40
S1 The area where the lower limit is stored or the lower limit data.
S2 The area where the upper limit is stored or the upper limit data.
S3 The area where the input value is stored or the input value data.
D The area where the output value is stored
Operands
O
erand
Relay Timer/Counter Register
Index
register
Constant
Index
WX WY WR WL SV EV DT LD FL I K H f
modifier device
S1 A A A A A A A A A A A A N/A A N/A
S2 A A A A A A A A A A A A N/A A N/A
S3 A A A A A A A A A A A A N/A A N/A
D N/A A A A A A A A A A N/A N/A N/A A N/A
Explanation of example
When the DT10 is K−100 and DT20 is K100.
Value of DT30
K−300
K−200
K−100 to K100
K200
K300
Value of DT40
K−200
K−100
K0
K100
K200
→
→
→
→
→
F287
P287
(PBAND)
(BAND)
16-bit data deadband control
vailable
N/A: Not Available