EasyManua.ls Logo

Panasonic FP-E - Page 966

Panasonic FP-E
1334 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
High−level Instructions
3 − 702
Program example
The “f1.047197 (radians of 60 degres)” is stored to DT20 and DT21 when the R0 turns on.
F319 ATAN, f1.73205, DT20
R0
Precautions during programming
D+1 and D is stored within the following range: − π/2 (radians) < [D+1, D] < π/2 (radians)
For FP0, this instruction F319 (ATAN) cannot be programmed in the interrupt program.
Flag conditions
・Error flag (R9007): Turns on and stays on when:
・Error flag (R9008): Turns on for an instant when:
− The area specified using the index modifier exceeds the limit.
− If data other than real number data is specified in S+1 and S.
− If result of processing is outside integer range when integer device is
specified in D+1 and D.
・= flag (R900B): Turns on when result of processing is recognized as “0.”
・Carry flag (R9009): Turns on for an instant when the result is overflowed.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com