Wiring FP∑ Positioning UNit
3-12
3.6 Connection of Home Input/Near Home Input Signals
This is the home signal input connection for the home return.
It should be connected to the Z phase output (Line driver output or Transistor output) of the motor driver,
or to an external switch and sensor.
Note:
We recommend using twisted - pair cables as the wiring between the positioning unit output and the
motor driver, or twisting the cables used.
3.6.1 Connection of Home Input (When connecting to motor driver Z phase
output)
3.6.2 Connection of Home Input (When connecting to an external
switch/sensor)