13
17
Specications
Type Standard type 2-output type Cable type
Model number
NPN output FX-501 FX-502 FX-505-C2
PNP output FX-501P FX-502P FX-505P-C2
Supply voltage 12 to 24V DC % (+10%/‑10%), ripple P‑P10% or less
Power consumption
Normal operation: 960mW or less (current consumption 40mA or less at 24V supply voltage)
Eco mode: 680mW or less (current consumption 28mA or less at 24V supply voltage)
Output (FX-502□ and FX-505□-C2 only:
output 1, output 2)
NPN open-collector transistor
Maximum sink current (see note 2):
FX-501: 100mA
FX-502, FX-505: 50mA
Applied voltage: 30V DC or less between sensing output and 0V
Residual voltage: 2V or less (see note 3) at maximum sink current
PNP open-collector transistor
Maximum source current (see note 2):
FX-501P: 100mA
FX-502P, FX-505P: 50mA
Applied voltage: 30V DC or less between sensing output and +V
Residual voltage: 2V or less (see note 3) at maximum source current
Number of outputs 1 2
Output operation Switchable either Light‑ON or Dark‑ON
Short‑circuit protection Incorporated
Response time H-SP: 25μs or less, FAST: 60μs or less, STD: 250μs or less, LONG: 2ms or less, U-LG: 4ms or less, HYPR: 24ms or less
Analog output (FX-505□-C2 only)
Output current: approx. 4 to 20mA
(display in H‑SP, FAST, STD: 0
to 4,000, display in LONG: 0 to
8,000 (see note 4))
Response time: 2ms or less
Zero point: within 4mA ±1%F.S.
Span: within 16mA ±5%F.S.
Linearity: within ±3%F.S.
Load resistance: 0 to 250Ω
External input (switchable with output 2 for
FX-502□)
Signal condition of NPN non-contact input:
High: +8V to +V DC or Open
Low: 0 to +1.2V DC (at 0.5mA source current)
Input impedance: Approx. 10kΩ
Signal condition of PNP non-contact input:
High: +4V to +V DC (at 3mA sink current)
Low: 0 to +0.6V DC or Open
Input impedance: Approx. 10kΩ
Protection IP40 (IEC)
Ambient temperature
‑10 to +55°C (no dew condensation or icing allowed)
For 4 to 7 units mounted in cascade: ‑10 to +50°C
For 8 to 12 units mounted in cascade: ‑10 to +45°C)
Storage: ‑20 to +70°C
Ambient humidity 35 to 85% RH, Storage: 35 to 85% RH
Material Enclosure: polycarbonate, switch: TPEE, protective cover: polycarbonate
Cable Cables are not supplied with the product. Select cables from the table below, 0.2 mm
2
6‑core cab tire cable, 2m
Weight (main body only) Approx. 15g Approx. 60g
Accessory FX-MB1 (Amplier protection seal): 1 set.
Notes:
1. Where measurement conditions have not been specied precisely, the conditions used were an ambient temperature of +23°C.
2. FX-501
: 50mA max. if 5 or more connector types are connected together (25mA for FX-502)
3. Only if you are using the quick‑connection cable (optional, cable length 5m).
4. If the digital display has been adjusted manually, the gures displayed may be outside the range.
Cable
Amplier
Cable length 1m Cable length 2m Cable length 5m
Main cable Sub cable Main cable Sub cable Main cable Sub cable
FX-501
CN‑73‑C1 CN‑71‑C1 CN‑73‑C2 CN‑71‑C2 CN‑73‑C5 CN‑71‑C5
FX-502
CN‑74‑C1 CN‑72‑C1 CN‑74‑C2 CN‑72‑C2 CN‑74‑C5 CN‑72‑C5
* You can extend the cable up to 100m max. with 0.3mm
2
or more
cable. However, in order to reduce noise, make the wiring as short
as possible.