EasyManua.ls Logo

Panasonic FX-501 Series

Panasonic FX-501 Series
13 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6
12
PRO mode (PRO)
When the mode indicator PRO (yellow) is ON, you can scroll through
the PRO menu (Pro1 to Pro7) and make advanced settings.
Note that FX-502□ has additional setting items in Pro3 and Pro4.
For details, refer to the diagrams for menu items below and the code set‑
tings table on page 10.
Pro1 menu items
*
SET
SET
SET
SET
SET
+,
-
+,
-
+,
-
+,
-
+,
-
+,
-
+,
-
+,
-
+,
-
+,
-
+,
-
+,
-
+,
-
+,
-
+,
-
SET
+,
-
+,
-
+,
-
+,
-
+,
-
+,
-
SET
<PRO1>
<PRO2>
ms 1/10ms
SETSET
+,
-
+,
-
≤250μs 2ms 4ms
24ms ≤60μs ≤25μs
+,
-
+,
-
+,
-
+,
-
+,
-
Response time
setting (note 1)
Timer setting
(note 2)
No timer
ON-delay
timer
OFF-delay
timer
Standard Large Small
Hysteresis
setting
One-shot
timer
ON-delay /
One-shot timer
(only sensing
output 1)
ON / OFF-delay
timer (only
sensing output 1)
Shift amount
setting
Displayed in
percentage
Incident light
intensity (note 1)
High emission
power
Saturation
correction
Middle emission
power
Low emission
power
Emission power
setting (note 3)
Correcting
<RUN mode>
Automatic
(note 4)
Automatic
Timer range
setting
Set
seconds
Notes
1. The incident light intensity displayed depends on the selected response time.
Response time Incident light intensity
STD, H‑SP, FAST Max. 4,000
LONG Max. 8,000
U‑LG, HYPR Max. 9,999
2. If you want to use the timer, make sure to select the timer range (last option in the
Pro1 menu) rst as the timer periods depend on the timer range.
Timer range Timer period Timer step
ms 0.5 – 9999ms 1ms
sec 0.5 – 32s 1ms
1/10ms 0.1 – 999.9ms 0.1ms
3. When the response time is set to high speed (
) and the hysteresis is set to
small (
), the emitting power automatically is set to low ( ) regardless of what
you have selected.
4. If the saturation correction is NG, it will not be displayed.
Pro2 menu items
*
+,
-
+,
-
SET
+,
-
SET
+,
-
SET
+,
-
+,
-
+,
-
+,
-
+,
-
SET
+,
-
+,
-
+,
-
+,
-
SET +,
-
SET
<PRO3>
<PRO2>
+,
-
+,
-
Lock OFF Lock ON
Teaching lock
setting
Hold OFF Hold ON
Time period hold
setting (note)
Turning OFF Turning ON
Eco setting Full
Setting of digital
display turning
Incident light
intensity
Displayed in
percentage
Digital display
setting
Peak /
bottom value
Eco OFF Eco ON
To clear the held value, set the time period hold function to
OFF once or turn the power OFF.
Pro3 menu items
+,
-
SET
+,
-
+,
-
+,
-
SET
+,
-
+,
-
+,
-
SET
+,
-
SET
<PRO3>
<PRO4>
+,
-
SET +,
-
+,
-
Data bank
loading setting
Automatic
Automatic
Only displayed in FX-502□
1 ch
Good
Blink Blinks
3 times
Blinks
3 times
Blink
Back up setting Backup ON Backup OFF
1 ch
YES Good
Data bank saving
setting
Input / output
setting
External inputSensing output 2
Changeable 1 to
8ch in + or -
Changeable 1 to
8ch in + or -
Yes
SET
+, –
SET key (confirm)
UP (+) key (select)
Automatic
DOWN (–) key (select)
Press the SET key .
MODE key
(select, cancel)
Press the UP (+) or
DOWN (–) key.
Device moves automati-
cally to the next item
MODE indicator: PRO (yellow)

Other manuals for Panasonic FX-501 Series