EasyManua.ls Logo

Panasonic HG-C Series - Limit Teaching (Digital)

Panasonic HG-C Series
7 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4
Span adjustment in ‘Rising differential mode’ or ‘Trailing differential
mode’
This mode is used to cancel the gradual changes in the measured values
and to only detect sudden changes.
To use the Rising differential mode or Trailing differential mode, preset ‘Ris-
ing differential mode’ oder ‘Trailing differential mode’ in the sensing output
setting of the PRO mode.
For the setting method, refer to section 12, “PRO mode setting.”
The threshold can be set by using the threshold value ne adjustment func-
tion, see section 8, “Threshold value ne adjustment function”.
1. Press the TEACH key.
2. Press the UP key or DOWN key to select
the span.
3. Press the TEACH key to set the span.
8
Threshold value ne adjustment function
The ne adjustment of the threshold can be performed in the measure-
ment display.
The ne adjustment of the threshold can be performed even after
teaching.
‘Normal sensing mode’, ‘Rising differential mode’ and ‘Trailing dif-
ferential mode’
Confirmed
Press the
TEACH key
Press the
UP/DOWN key
Press the
UP/DOWN key
(automatically
set after 3
seconds.)
Window comparator mode
When the sensing output is set to window comparator mode, the display
and can be changed only by pressing the TEACH key for 1
second.
Automatic
Press the TEACH
key 1 second
Change the
threshold value
Measurement
display
When performing a ne adjustment of the threshold of or
, press the UP key or DOWN key. After or is displayed, the
ne adjustment of the threshold can be performed.
Confirmed
Automatic
(automatically
set after 3
seconds.)
Press the
TEACH key
Press the
UP/DOWN key
Press the
UP/DOWN key
or
9
Peak / bottom hold function
The peak / bottom hold function is for displaying the peak value and the bot-
tom value.
When the zero set function is executed while the peak / bottom hold func-
tion is set to “Peak hold” or “Bottom hold”, the held measured value will be
reset.
Press the TEACH
key and UP
key
simultaneously for 3
seconds.
Press the
UP/DOWN key
Press the
TEACH key
Confirmed
Select
or
or
or
(automatically
set after 3
seconds.)
Digital
display
Description Function
Hold function release
Releases the hold status, and outputs
the current measured value
Peak hold Holds maximum measured value
Bottom hold Holds minimum measured value
10
Zero set function
The zero set function is the function to compulsory set the measured value
to ‘zero’.
The zero set indicator (yellow) will turn ON when the zero set is valid.
When the display setting is set to Offset, the zero set function cannot be
set.
“Zero set” setting
Confirmed
Press the UP and
DOWN key
simultaneously for 3
seconds.
All manuals and user guides at all-guides.com

Other manuals for Panasonic HG-C Series

Related product manuals