EN-24
Installation Instructions
4-Wire Branch Circuit
Refer to Figure 2:
Disconnect ground from neutral at free
end of conduit.
Connect the green GROUND wire from
the oven to the GROUND wire in the
junction box (bare or green colored wire).
Connect the red and black leads from the
oven to the corresponding HOT Wires in
the junction box.
Connect the white wire from the oven to
the NEUTRAL (gray or white) wire in the
junction box.
Connect the local codes and power
supply codes using a terminal.
The terminal uses a thing adapting to the
wire of the cord.
Ungrounded Neutral
Cable from
power supply
Cable
from oven
Junction box
Red wires
Black wires
White wires
Bare or
green wire
U.L.-listed conduit
connector
Figure 2
Important: Use twist-on connector
with square-wire spring
Square-wire spring
Or
From the oven
Terminal Block
From power supply