Operation
Overheat detector
If the printer is printing continuously for extended periods of time, the
print head may become overheated.
When
this occurs,
an
internal
protective circuit will cause the printer
to
pause until the head
temperature decreases sufficiently, at which time the printer will
automatically resume printing without loss of data. This feature is
included to extend the life of the print head.
3.5 Initialization
The printer is initialized under the following conditions:
the
AC
power is turned
on
the PRIME signal is received
the RESET printer command is received
When the printer is initialized, the following conditions are set:
-the
print buffer is cleared
-the
receive buffer is cleared (not cleared
by
RESET PRINTER
command)
-the
download character buffer is cleared (not cleared by PRIME
signal in IBM Proprinter X24 mode or
by
RESET PRINTER
command)
-the
Initial Setup modes are
read
and
set
-horizontal
tabs are set every 8 columns
-vertical
tab settings are cleared
-all
modes set by control
and
escape commands will
be
cleared
-present
form position is designated
as
top of form
-the
Self Test mode is cleared
-the
Control Table settings are
read
and
set
-Control
Panel settings are not changed by PRIME signal or RESET
PRINTER command'
-the
print head goes to the home position
'Some software packages send PRIME signal
at
the beginning of their
programs. Print modes set
by
the Control Table will not change.
3-17