18
• 5. How to returned to Normal Display:
Turn the power off and on, to exit from Error code display mode.
NOTE:
The error code can not be initialized by the unit only.
SOFT CPU Reset 3000 0001
|
0007
NMI reset
Non Mask-able Interrupt
(30000001-30000007 are caused by factors)
Card Card 3100 0001 Card logic error
SD card data line or IC6001 (VENUS 2)
0002 Card physical error
SD card data line or IC6001 (VENUS 2)
0004 Write error
SD card data line or IC6001 (VENUS 2)
0005 Format error
SD card data line or IC6001 (VENUS 2)
CPU,
ASIC hard
Stop 3800 0001 Camera task finish process time out.
Communication between Lens system and IC6001 (VENUS 2)
0002 Camera task invalid code error.
IC6001 (VENUS 2)
0100 File time out error in recording motion image
IC6001 (VENUS 2)
0200 File data send error in recording motion image
IC6001 (VENUS 2)
Monitor 1000 AF frame movement check time out.
IC6001 (VENUS 2)
Operation Power on 3B00 0000 FLASHROM processing early period of camera during movement.
Zoom Zoom 3C00 0000 I do not complete zoom lens processing
Zoom lens
3500 0000 I jumped into dummy processing
(0-7bit : command, 8-15bit : Status)
3502 0000 Though record preprocessing is necessary, it is not called.
3503 0000 Though record preprocessing is necessary, it is not completed.
Attribute Main item Sub item Error code Contents (Upper)