— 34 —
NC-HU301P, NC-HU401P
5.2. Actual Wiring Diagram (in case of 3.0L)
Caution
Return to original wiring after repair.
Lead wires touch to the surface of
parts, and may cause fault or
power shock.
Boiling Heater (832.6-910W)
Lead Wire Assy D
Ceramic Terminal
Lead Wire K
Lead Wire J
Funen-Ben
Lead Wire H (Blue)
Earth Wire Assy (Green)
## For Thailand :
(Yellow spiral green)
Peg Frame Comp.
AC 220V-230V
Funen Tube
Lead Wire Assy A (White)
Lead Wire Assy B
Thermal fuse (Indication: 157°C)
Thermal fuse Comp.
Lead Wire Assy C
Motor Tube (Yellow)
Lead Wire Assy E
(12 cores)
Pump Comp.
Control Unit A
Control Unit B
Lead Wire M
Thermistor Assy
Marking colur: Light Green
Keep Warm Heater (112-122W)

Table of Contents