6.8. Stirrer motor
1. Remove the motor cover by breaking off at the 8 spots
indicated by arrows with a cutter or the like.
NOTE:
After removing the motor cover, be sure that cut
portions are properly trimmed or bent to the inside
so that no sharp edges will be exposed to outside.
2. Disconnect 2 lead wires connected to the stirrer motor.
3. Remove the stirrer motor by removing screw.
NOTE:
After reinstalling the new stirrer motor and
reconnecting the 2 lead wires, reinstall the motor
cover by rotating it around 180, tucking the 2 tabs
under the base in the 2 provided slots, then screw
the single tab to the base using a 4mm × 6mm
screw.
6.9. Convection fan motor and
convection heater
1. Remove 1 screw holding side cover on cavity back plate.
2. Remove 1 screw holding side cover on the side of back
cover, then remove side cover & circuit breaker.
NOTE:
When reassembling the side cover, the edges may
damage the lead wire if not handled with care.
3. Disconnect 2 lead wires from convection heater terminals.
16