2. The setting temperature
The temperature, when it set on 4
C.
The OFF/ON temperature value corresponding to each ATC temperature is as shown in the next table.
3. OFF/ON temperature according to PC temperature setting
The OFF/ON temperature corresponding to each PC temperature setting is as shown in the following tables.
Moreover TPOFF and TPON that exist in the following table are considered the temperature calculated by the OFF/
ON temperature value at 4
C setting.
*: TPOFF and TPON that exist in the following table are considered the temperature calculated by
the OFF/ON temperature value at 4
C setting.
ATC correction temperature Turning off temperature
(OFF temperature)
Turning on temperature
(ON temperature)
40C or above 9.1C11.8C
11C to 3C 8.1 -
(8.1 - 9.1)
(ATC correction temperature - 33)/
(40-33)
11.1 -
(11.1 - 11.8)
(ATC correction temperature-33)/
(40-33)
33C or above 8.1C11.1C
11C to 33C 7.0 -
(7.0 - 8.1)
(ATC correction temperature - 21)/
(33-21)
9.0 -
(9.0 - 11.1)
(ATC correction temperature-21)/
(33-21)
21C or above 7.0C9.0C
11C to 21C 6.0 -
(6.0 - 7.0)
(ATC correction temperature - 10)/
(21-10)
7.5 -
(7.5 - 9.0)
(ATC correction temperature-10)/
(21-10)
10C or above 6.0C7.5C
ATC correction temperature Turning off temperature
(OFF temperature)
Turning on temperature
(ON temperature)
(7C) setting Tfoff + 2.0C TFon + 2.0C
(6C) setting Tfoff + 2.0C (2 / 3) TFon + 2.0C (2 / 3)
(5C) setting Tfoff + 2.0C (1 / 3) TFon + 2.0C (1 / 3)
(4C) setting Tfoff TFon
(3C) setting Tfoff - 3.0C (1 / 3) TFon - 3.0C (1 / 3)
(2C) setting Tfoff - 3.0C (2 / 3) TFon - 3.0C (2 / 3)
(1C) setting Tfoff - 3.0C TFon - 3.0C