EasyManua.ls Logo

Panasonic NR-B53V2 - 5.12 Antibacterial Control

Panasonic NR-B53V2
83 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
24
5.12. Antibacterial deodorant control (Deodorizing fan control, Antibacterial
PC-LED control)
5.12.1. ON/OFF control of Deodorizing fan
Press and hold the Hygiene Plus button for 0.5 second. “Hygiene Plus” indicator lights up and Antibacterial deodorant
control starts.
Press and hold the Hygiene Plus button for 0.5 second “Hygiene Plus” indicator lights off and Antibacterial deodorant
control stops.
ON/OFF of Deodorizing fan is controlled by ATC sensor, FCC sensor, PCC sensor and PC door open or close.
5.12.2. Operation control of Deodorizing fan
1. Press and hold the Hygiene Plus button for 0.5 second.
First of all, it enters A mode that is rapid deodorization driving, the deodorizing fan drives for 120 minutes
continuously.
After starting B mode that is normal deodorization driving, the deodorizing fan control starts.
2. Press and hold the Hygiene Plus button for 0.5 second when antibacterial deodorant control starts.
When the antibacterial deodorant control stops (C mode), the deodorizing fan stops.
3. When power supply is turned on.
The deodorizing fan stops, even if A, B or C mode, when ATC is 34
C or above and while FCC is 27C or above.
4. When PC door open.
The deodorizing fan stop forcibly even if A, B or C mode, While PC door opens. (To be dewy prevention, frost
prevention)
5.12.3. Antibacterial PC-LED control
1. Basic operation
In A or B mode of the deodorizing fan control, antibacterial PC-LED turn on while the deodorizing fan drives. (If the
fan stops, the LED is turned off.)
2. Exceptional control
In A or B mode of the deodorizing fan control, antibacterial PC-LED is turned on forcibly while PC door opens.
5.13. Photosynthesis-freshness-improving effect control
Input: To press and hold the Vitamin-Safe button for 0.5 second.
Output: LED of VC (Green LED, Blue LED)
Content of processing: Press and hold the Vitamin-Safe button for 0.5 second, Vitamin-Safe indicator lights up and both
the blue LED and the green LED blink at the same time. It is operating a photosynthesis-freshness-improving effect
control. While operating the control, press and hold the Vitamin-Safe button for 0.5 second, the control stops and
“Vitamin-Safe” indicator lights and LED of VC are turned off.
AT 10C or below 11C to 21C22C to 28C29C or above
When compressor ON When PC is cooled ON ON ON ON
When FC is cooled ON ON ON ON
When Compressor OFF
The fan drive
for 30 minutes
after compres-
sor OFF
The fan drive
for 10 minutes
after compres-
sor OFF
The fan OFF The fan OFF
Photosynthesis-freshness-improving
effect control
While operating the control While stop
Blue LED 40Hz flashing
(ON/OFF: at each of 9.1msec)
OFF
Green LED OFF

Table of Contents