EasyManua.ls Logo

Panasonic PT-CW230E - Screen Aspect Ratio Settings; Standard Screen Modes (Normal, Full, Wide, Zoom); Advanced Screen Modes (True, Natural Wide, Custom)

Panasonic PT-CW230E
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
-47-
Troubleshooting
Error Error code Error infomation
Normal 0 -
Power Failure
1000 MAIN, P_FAIL Errors on the power supply lines or Fan control
1001 WHEEL, ERROR Error on the color wheel
Temperature Error
2000 Sensor A detects abnormal temperature. (IC8801-ROOM)
2001 Sensor A fails measurement. (IC8801)
2100 Sensor B detects abnormal temperature. (IC8821-LAMP)
2101 Sensor B fails measurement. (IC8821)
2102 Sensors B-A temperature error.
2200 Sensor C detects abnormal temperature. (IC8811-DMD)
2201 Sensor C fails measurement. (IC8811)
2202 Sensors C-A temperature error.
Lamp Error
3000 Lamp1 fails on
3001 Lamp1 goes out
3002 Communication Error on Lamp1
Error log
This projector provides the error history log function. To
check the logs, you need to enter the service mode and
select the group "220" and no. "0" to "49". The error code is
displayed on the data column. The description of the error
code is listed on the table below.
* How to enter the service mode and select the group, item
and data value, see "Service adjustment menu opera-
tion".
Group
No.
Item
No.
Data
(Error Code)
220 0
1
2
3
:
:
49
[
<- Latest Error
[
[
[
:
:
[
How to reset the error log
1. Enter the service mode, and select the group "220" and no. "50".
2 The history log will be reset when the data value is set to "10". The value automatically returns to "0".
* How to enter the service mode and select the group, item and data value, see "Service adjustment menu operation".