Chapter 4Settings — [NETWORK] menu
120 - ENGLISH
Contents of E-mail sent
Example of E-mail sent when E-mail is set
The following E-mail is sent when the E-mail settings have been established.
=== Panasonic projector report (CONFI G URE) ===
Projector Type : EZ 580
Serial No : SN9250024
----- E-mail setup data -----
TEMPERAT URE WARNING SETUP
MINIMUM TIME at [ 30] minutes interval
INTAKE AIR T EMPERAT URE Over [ 36 degC / 96 degF ]
ERROR [ O N ]
LAMP RUNTIME [ ON ] at REMAIN [ 400] H
LAMP RUNTIME [ ON ] at REMAIN [ 500] H
INTAKE AIR TEMPERATURE [ ON ]
PERI ODIC REPORT
Sunday [ O F F ] Monday [ O F F ] Tuesday [ O F F ] Wednesday [ O F F ]
Thursday [ O F F ] Friday [ O F F ] Saturday [ O F F ]
00:00 [ O FF ] 01:00 [ O F F ] 02: 00 [ O F F ] 03: 00 [ OFF ]
04:00 [ O FF ] 05:00 [ O F F ] 06: 00 [ O F F ] 07: 00 [ OFF ]
08:00 [ O FF ] 09:00 [ O F F ] 10: 00 [ O F F ] 11: 00 [ OFF ]
12:00 [ O FF ] 13:00 [ O F F ] 14: 00 [ O F F ] 15: 00 [ OFF ]
16:00 [ O FF ] 17:00 [ O F F ] 18: 00 [ O F F ] 19: 00 [ OFF ]
20:00 [ O FF ] 21:00 [ O F F ] 22: 00 [ O F F ] 23: 00 [ OFF ]
----- check system -----
MAI N CPU BUS [ OK ]
FAN [ OK ]
INTAKE AIR TEMPERATURE [ OK ]
AROUND LAMP TEMPERATURE [ OK ]
LAMP REMAIN TIME [ OK ]
LAMP STATUS [ OK ]
APERTURE(CO NTRAST-SHUT TER) [ O K ]
SHUTTER(MUTE-SHUT T ER) [ O K ]
INTAKE AIR TEMP.SENSOR [ OK ]
AROUND LAMP TEMP.SENSOR [ OK ]
BATTERY [ OK ]
AIRFLOW SENSOR [ OK ]
LENS MO UNTER [ OK ]
COVER OPEN [ OK ]
PRESSURE SENSOR [ OK ]
ANGLE SENSOR [ OK ]
FI LTER UNIT [ OK ]
AIR FI LTER [ OK ]
(Error code00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00)
Int ake air t emperature : 45 degC / 113 degF
Around lamp temperat ure : 42 degC / 107 degF
PROJECTO R RUNTI ME 2500 H
LAMP ECO 100 H
LAMP NORMAL 200 H
LAMP REMAIN 1900 H
-------- Current status --------
MAIN VERSION 1.00
NETWORK VERSION 1.00
SUB VERSION 1.00
LAMP STATUS LAMP=ON
INPUT SIGNAL HDMI
SIGNAL NAME XGA60
SIG NAL FREQUENCY 65.4kHz / 54. 4Hz
REMOTE2 STATUS ENABLE
----- Wired Network configuration -----
DHCP Client OF F
IP address 192. 168.0. 8
MAC address cc: 7e:e8: 00:00: 00
Tue Jun 04 22:30:14:2013
----- Memo -----
Note