9.4.3. Set up of PC-EVR Adjustment
Program
1. Turn on the PC and install the PC-EVR Adjustment
Program into the PC.
2. Execute the “kdv2008.exe” file by double clicking to start up
the PC-EVR adjustment program.
The main menu will be displayed.
3. Select the appropriate model.
4. Turn on the camcorder and set to PC connection (COM)
mode. Then click "Start".
Fig. E3-1
5. When the communication is complete, the following dialog
will appear.
Click "Yes" and "Save" to save the EEPROM data.
Fig. E3-2
6. When EEPROM data has been saved, the menu will
appear.
To perform each adjustment, display the adjustment menu
by selecting from "Camera Adjust" or "VCR Adjust" and
select each adjustment item.
Fig. E3-3
Note:
The adjusted data is stored in the EEPROM IC after
each adjustment.
7. After adjustment, to close the software, select "Exit" in the
File menu or close the window.
Fig. E3-4
8. To release the PC connection (COM) mode, push the
[PHOTO SHOT], [RECORDING START/STOP] and
[MANUAL AF/MF] simultaneously for 3 seconds with the
USB Cable disconnected.
34
PV-GS90P