Playback
frequency
response
Equipment:
*
VTVM
*
Oscilloscope
*
Test
tape---C-FH
Playback
gain
Equipment:
*VTVM
*
Oscilloscope
*
Test
tape--»C-FH
MEASUREMENT
&
ADJUSTMENT
.
Test
equipment
connection
is
as
same
as
“Head
azimuth
adjustment”
but
use
the
test
tape
(C-FH)
instead
of
head
azimuth
tape
(See
fig.
11).
.
Place
UNIT
into
playback
mode.
.
Play
frequency
response
test
tape
(C-FH).
.
Measure
output
level
at
10kHz,
8kHz,
4kHz,
1kHz,
125Hz
and
63Hz
and
compare
each
output
level
with
standard
frequency
333Hz,
at
LINE
OUT.
.
Make
measurement
for
both
channels.
.
Make
sure
that
the
measured
value
is
within
the
range
specified
in
the
frequency
response
chart.
Playback
frequency
response
chart
333Hz
400Hz
125Hz
—250Hz
6.3kHz
10kHz
Fig.
11
Adjustment
1.
If
the
measured
value
decreases
at
high
frequency
range.
*
Short
the
connection
point
(A)
or
unsolder
connection
point
(C).
See
fig.
19
on
page
12.
.
If
the
measured
value
increases
at
high
frequency
range.
*
Short
the
connection
point
(B)
or
(C).
.
Test
equipment
connection
is
shown
in
fig.
7.
2.
Play
standard
recording
level
portion
on
test
tape
(C-FH
333H2z),
and
|
using
VTVM
measure
the
output
level
at
LINE
OUT
jack.
.
Make
measurement
for
both
channels.
|
Standard
Value:
0.42
V
(—7
dB)
Adjustment
1.
If
measured
value
is
not
standard,
adjust
VR3
(L-CH),
VR4
(R-CH)
(See
fig.
20
on
page
12).
2.
After
adjustment,
check
"Playback
frequency
response”
again.
Playback
S/N
ratio
Equipment:
*
VTVM
*
Oscilloscope
*
Test
tape---C-FH
*
Empty
cassette
2.
Play
standard
recording
level
test
tape
(C-FH
333Hz)
and
read
out-
REMARKS
*
Playback
mode
*
Playback
mode
.
Test
equipment
connection
is
shown
in
fig.
7.
put
level
on
VTVM.
Refer
to
“Playback
gain
adjustment”.
.
Place
empty
cassette
(which
has
been
cut)
and
play
again.
.
Measure
noise
level
at
this
time
using
VTVM,
and
determine
ratio
of
this
level
to
test
tape
output
signal
voltage
(333Hz).
|
Standard
Value:
Greater
than
46 dB
*
Playback