1-1. Unit Specifications
4-Way Cassette Type S-125PU2E5B / U-125PZ2R8
INDOOR MODEL
S-125PU2E5B - -
PANEL MODEL
Standard type:CZ-KPU3:ECONAVI type:CZ-KPU3A
- -
OUTDOOR MODEL
- U-125PZ2R8 -
Branch pipe MODEL
-
Performance test condition
ISO5151 / AS/NZS3823.1
Power supply
ø, Hz
1Ø 50Hz 3Ø 50Hz
V
- 230V 240V - 400V 415V Min Max
C
O
O
L
I
N
G
Capacity
kW
- 12.5 12.5 - - - 3.2 13.5
BTU/h
- 42700 42700 - - - 10900 46100
Current A
- 0.88 0.85 - 5.20 5.00 - -
Input power
W
- 110 110 - 3.380k 3.380k - -
TOTAL W
- - 3.490k 3.490k 600 4.800k
Annual consumption TOTAL kWh *
4
- - - - 1745 - - -
EER/ AEER/ STAR RATING TOTAL (W/W/-)
- - - -
3.58/3.52/-
3.58 5.33 2.81
Power factor %
- - - - 94 94 - -
Noise indoor
dB-A (H/M/L) *
6
46/39/33 - - -
Power Level dB
61/54/48 - - -
Noise outdoor
dB-A (H/L)
- 55/- - -
Power Level dB
- 70/- - -
H
E
A
T
I
N
G
Capacity
kW
- 12.5 12.5 - - - 3.3 15.0
BTU/h
- 42700 42700 - - - 11300 51200
Current A
- 0.87 0.84 - 4.15 4.00 - -
Input power
W
- 105 105 - 2.715k 2.715k - -
TOTAL W
- - 2.820k 2.820k 600 4.200k
COP/ ACOP/ STAR RATING TOTAL (W/W/-)
- - - -
4.43/4.33/-
4.43 5.50 3.57
Power factor %
- - - - 94 94 - -
Noise indoor
dB-A (H/M/L) *
6
46/39/33 - - -
Power Level dB
61/54/48 - - -
Noise outdoor
dB-A (H/L)
- 55/- - -
Power Level dB
- 70/- - -
EXTRA LOW TEMP
Total capacity(kW) / Input power(W) / COP
- -
Max Current (A) / Max Input power (W)
- 0.88/110 0.85/110 -
10.0/6500 10.0/6750
-
Starting current (A) / Comp output (W)
- - - -
5.20/2.80k 5.00/2.80k
-
Network Impedance (ΩMAX.)
- - -
Fan motor output (Indoor/Outdoor) W
90 120 -
Moisture removal volume L/h(Pt/h)
4.8 (10.1) - -
External static pressure Pa
- - -
Indoor
Air ow *6
Cooling m
3
/min (ft
3
/min)
37.0/27.0/19.0
(1307)/(953)/(671)
- - -
Heating m
3
/min (ft
3
/min)
37.0/27.0/19.0
(1307)/(953)/(671)
- - -
Outdoor
Air ow
Cooling m
3
/min (ft
3
/min)
- 86.0 (3037) - -
Heating m
3
/min (ft
3
/min)
- 78.0 (2754) - -
Refrigerant type / amount
g
(oz)
-
R32 2.98k (105.1)
-
Product dimension
Height mm(inch)
319 (12-9/16) 996 (39- 7/32) -
Width mm(inch)
840 (33-5/64) 980 (38-37/64) -
Depth mm(inch)
840 (33-5/64) 370 (14- 9/16) -
Product dimension (Panel)
H×W×D mm, inch
33.5×950×950
1-11/32 × 37-13/32 × 37-13/32
- -
Packing dimension
Height mm(inch)
365 (14-3/8) 1134 (44-41/64) -
Width mm(inch)
898 (35-3/8) 1095 (43-7/64) -
Depth mm(inch)
898 (35-3/8) 529 (20-53/64) -
Weight
(NET) k
g
(lb)
25 (55) 94 (207) -
(GROSS) k
g
(lb)
32 (71) 102 (224) -
Panel (NET) k
g
(lb)
5 (11) - -
Layers limit (actually)
11 (12)
2 (3) -
Operation condition
Cool (DBT) 18°C ~ 32°C -10°C ~ 43°C
-
Heat (DBT) 16°C ~ 30°C -15°C ~ 24°C
-
MAX WORKING PRESSURE HP/LP
MPa (bar) 4.15/2.55 (41.5/25.5)
-
P
I
P
I
N
G
Pipe diameter mm (inch)
(Liquid)Ø9.52(3/8) (Gas)Ø15.88(5/8) (Liquid)Ø9.52(3/8) (Gas)Ø15.88(5/8)
-
Connecting method, Standard length m(ft)
ared type, 5.0(16.4) ared type, 5.0(16.4) -
Pipe length range m (ft)
5 ~ 50m (16.4 ~164.0) -
Indoor unit & Outdoor unit height difference m (ft)
15m(OD located lower)/30m(OD located higher) (49.2/98.4) -
Add gas amount
g
/m (oz/ft)
45
g
/m (0.484) -
Pipe length for additional gas m (ft)
30m (98.4) -
*1 In case it is necessary to indicate the air flow volume in (l/s), the value in (m³/min.) shall be multiplied by 16.7 and rounded down the decimal point.
*2 If the EUROVENT Certified models can be operated under the "extra-low"temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage
230V shall be used.
*3 Network Impedance shall be applicable for EUROPE and CHINA models.
*4 The annual consumption is calculated by multiplying the input power at 230V(400V) by an average of 500 hours per year in cooling mode.
*5 EER and COP classification is at 230V(400V) only in accordance with EU directive 2002/31/EC.
*6 H: High at setting 5 stage (Level 5), M: Middle at setting 5 stage (Level 3), L: Low at setting 5 stage (Level 1)