1-1-8
11
Single-Type
1-1. Unit Specifications
4-Way Cassette Type S-140PU2E5B / U-140PZ2R5
INDOOR MODEL
S-140PU2E5B - -
PANEL MODEL
Standard type:CZ-KPU3:ECONAVI type:CZ-KPU3A
- -
OUTDOOR MODEL
- U-140PZ2R5 -
Branch pipe MODEL
-
Performance test condition
ISO5151 / AS/NZS3823.1
Power supply
ø, Hz
1Ø 50Hz 1Ø 50Hz
V
- 230V 240V - 230V 240V Min Max
C
O
O
L
I
N
G
Capacity
kW
- 14.0 14.0 - - - 3.3 15.0
BTU/h
- 47800 47800 - - - 11300 51200
Current A
- 0.94 0.91 - 19.5 18.7 - -
Input power
W
- 120 120 - 4.220k 4.220k - -
TOTAL W
- - 4.340k 4.340k 620 5.500k
Annual consumption TOTAL kWh *
4
- - - - 2170 - - -
EER/ AEER/ STAR RATING TOTAL (W/W/-)
- - - -
3.23/3.18/1.5
3.23 5.32 2.73
Power factor %
- - - - 94 94 - -
Noise indoor
dB-A (H/M/L) *
6
47/40/34 - - -
Power Level dB
62/55/49 - - -
Noise outdoor
dB-A (H/L)
- 56/- - -
Power Level dB
- 71/- - -
H
E
A
T
I
N
G
Capacity
kW
- 14.0 14.0 - - - 3.4 16.0
BTU/h
- 47800 47800 - - - 11600 54600
Current A
- 0.93 0.90 - 15.0 14.3 - -
Input power
W
- 115 115 - 3.235k 3.235k - -
TOTAL W
- - 3.350k 3.350k 620 4.800k
COP/ ACOP/ STAR RATING TOTAL (W/W/-)
- - - -
4.18/4.10/3.5
4.18 5.48 3.33
Power factor %
- - - - 94 94 - -
Noise indoor
dB-A (H/M/L) *
6
47/40/34 - - -
Power Level dB
62/55/49 - - -
Noise outdoor
dB-A (H/L)
- 56/- - -
Power Level dB
- 71/- - -
EXTRA LOW TEMP
Total capacity(kW) / Input power(W) / COP
- -
Max Current (A) / Max Input power (W)
- 0.94/120 0.91/120 -
30.0/6500 30.0/6800
-
Starting current (A) / Comp output (W)
- - - -
19.5/3.00k 18.7/3.00k
-
Network Impedance (ΩMAX.)
- - -
Fan motor output (Indoor/Outdoor) W
90 120 -
Moisture removal volume L/h(Pt/h)
6.0 (12.6) - -
External static pressure Pa
- - -
Indoor
Air ow *6
Cooling m
3
/min (ft
3
/min)
38.0/29.0/20.0
(1342)/(1024)/(706)
- - -
Heating m
3
/min (ft
3
/min)
38.0/29.0/20.0
(1342)/(1024)/(706)
- - -
Outdoor
Air ow
Cooling m
3
/min (ft
3
/min)
- 89.0 (3143) - -
Heating m
3
/min (ft
3
/min)
- 83.0 (2931) - -
Refrigerant type / amount
g
(oz)
-
R32 2.98k (105.1)
-
Product dimension
Height mm(inch)
319 (12-9/16) 996 (39- 7/32) -
Width mm(inch)
840 (33-5/64) 980 (38-37/64) -
Depth mm(inch)
840 (33-5/64) 370 (14- 9/16) -
Product dimension (Panel)
H×W×D mm, inch
33.5×950×950
1-11/32 × 37-13/32 × 37-13/32
- -
Packing dimension
Height mm(inch)
365 (14-3/8) 1134 (44-41/64) -
Width mm(inch)
898 (35-3/8) 1095 (43-7/64) -
Depth mm(inch)
898 (35-3/8) 529 (20-53/64) -
Weight
(NET) k
g
(lb)
25 (55) 94 (207) -
(GROSS) k
g
(lb)
32 (71) 102 (224) -
Panel (NET) k
g
(lb)
5 (11) - -
Layers limit (actually)
11 (12)
2 (3) -
Operation condition
Cool (DBT) 18°C ~ 32°C -10°C ~ 43°C
-
Heat (DBT) 16°C ~ 30°C -15°C ~ 24°C
-
MAX WORKING PRESSURE HP/LP
MPa (bar) 4.15/2.55 (41.5/25.5)
-
P
I
P
I
N
G
Pipe diameter mm (inch)
(Liquid)Ø9.52(3/8) (Gas)Ø15.88(5/8) (Liquid)Ø9.52(3/8) (Gas)Ø15.88(5/8)
-
Connecting method, Standard length m(ft)
ared type, 5.0(16.4) ared type, 5.0(16.4) -
Pipe length range m (ft)
5 ~ 50m (16.4 ~164.0) -
Indoor unit & Outdoor unit height difference m (ft)
15m(OD located lower)/30m(OD located higher) (49.2/98.4) -
Add gas amount
g
/m (oz/ft)
45
g
/m (0.484) -
Pipe length for additional gas m (ft)
30m (98.4) -
*1 In case it is necessary to indicate the air flow volume in (l/s), the value in (m³/min.) shall be multiplied by 16.7 and rounded down the decimal point.
*2 If the EUROVENT Certified models can be operated under the "extra-low"temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage
230V shall be used.
*3 Network Impedance shall be applicable for EUROPE and CHINA models.
*4 The annual consumption is calculated by multiplying the input power at 230V(400V) by an average of 500 hours per year in cooling mode.
*5 EER and COP classification is at 230V(400V) only in accordance with EU directive 2002/31/EC.
*6 H: High at setting 5 stage (Level 5), M: Middle at setting 5 stage (Level 3), L: Low at setting 5 stage (Level 1)
SM830266-00_大洋州向けR32シングルTD&SM.indb 8 18/03/29 10:19:22