1-1-10
11
Single-Type
1-1. Unit Specifications
Ducted Type S-60PE1R5B / U-60PZ2R5
INDOOR MODEL S–60PE1R5B
PANEL MODEL
OUTDOOR MODEL U-60PZ2R5
Branch pipe MODEL
Performance test condition ISO13253 / AS/NZS3823.1
Power supply
ø, Hz 1ø 50 Hz 1ø 50 Hz
V 230 V 240 V 230 V 240 V Min Max
C
O
O
L
I
N
G
Capacity
kW 6.0 6.0 2.0 7.1
BTU/h 20500 20500 6800 24200
Current A 0.85 0.86 8.05 7.70
Input power
W 190 200 1.670k 1.660k
TOTAL W 1.860k 1.860k 450 2.350 k
Annual consumption TOTAL kWh *
4
930 - -
EER/ AEER/ STAR RATING TOTAL (W/W/-)
3.23/3.13/-
3.23 4.44 3.02
Power factor % 90 90
Noise indoor
dB-A (H/M/L) 43/41/40
Power Level dB 60/58/57
Noise outdoor
dB-A (H/L) 46/–
Power Level dB 65/–
H
E
A
T
I
N
G
Capacity
kW 6.0 6.0 1.8 7.6
BTU/h 20500 20500 6100 25900
Current A 0.85 0.86 6.45 6.15 -
Input power
W 190 200 1.340k 1.330k -
TOTAL W 1.530k 1.530k 380 2.450 k
COP/ ACOP/ STAR RATING TOTAL (W/W/-)
3.92/3.78/-
3.92 4.74 3.10
Power factor % 90 90
Noise indoor
dB-A (H/M/L) 43/41/40
Power Level dB 60/58/57
Noise outdoor
dB-A (H/L) 48/–
Power Level dB 66/–
EXTRA LOW TEMP
Total capacity(kW) / Input power(W) / COP
Max Current (A) / Max Input power (W) 0.89/200 0.90/210
16.4/3.39k 16.4/3.54k
Starting current (A) / Comp output (W)
8.05/1.7k 7.70/1.7k
Network Impedance (ΩMAX.)
Fan motor output (Indoor/Outdoor) W 90 60
Moisture removal volume L/h(Pt/h) 3.4 (7.1)
External static pressure Pa 70 (MIN10 – MAX100)
Indoor
Air ow
Cooling m
3
/min (ft
3
/min) 22/20/16 (777/706/565)
Heating m
3
/min (ft
3
/min) 22/20/16 (777/706/565)
Outdoor
Air ow
Cooling m
3
/min (ft
3
/min) 45 (1589)
Heating m
3
/min (ft
3
/min) 45 (1589)
Refrigerant type / amount
g
(oz) R32 1.45 k (51.1)
Product dimension
Height mm(inch) 290 (11–13/32) 695 (27–23/64)
Width mm(inch) 1100(+100)
(43–5/16(+3–15/16))
875 (34–29/64)
Depth mm(inch) 700 (27–9/16) 320 (12–38/64)
Packing dimension
Height mm(inch) 375 (14-49/64) 761 (29-61/64)
Width mm(inch) 1315 (51-49/64) 1049 (41-19/64)
Depth mm(inch) 812 (31-31/32) 460 (18-7/64)
Weight
(NET) k
g
(lb) 35 (77) 44 (97)
(GROSS) k
g
(lb) 42 (93) 49 (108)
Layers limit (actually) 6(7) 3(4)
Operation condition
Cool (DBT) 18˚C – 32˚C -10˚C – 43˚C
Heat (DBT) 16˚C – 30˚C -15˚C – 24˚C
MAX WORKING PRESSURE HP/LP MPa (bar) 4.15/2.55 (41.5/25.5)
P
I
P
I
N
G
Pipe diameter mm (inch)
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8) (Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
Connecting method, Standard length m(ft) ared type, 5.0(16.4) ared type, 5.0(16.4)
Pipe length range m (ft)
3 ~ 40m (9.8 ~131.2)
Indoor unit & Outdoor unit height difference m (ft)
15m(OD located lower)/30m(OD located higher) (49.2/98.4)
Add gas amount
g
/m (oz/ft)
35
g
/m (0.376)
Pipe length for additional gas m (ft)
30m (98.4)
*1 In case it is necessary to indicate the air flow volume in (l/s), the value in (m³/min.) shall be multiplied by 16.7 and rounded down the decimal point.
*2 If the EUROVENT Certified models can be operated under the "extra-low"temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage
230V shall be used.
*3 Network Impedance shall be applicable for EUROPE and CHINA models.
*4 The annual consumption is calculated by multiplying the input power at 230V(400V) by an average of 500 hours per year in cooling mode.
*5 EER and COP classification is at 230V(400V) only in accordance with EU directive 2002/31/EC.
SM830266-00_大洋州向けR32シングルTD&SM.indb 10 18/03/29 10:19:22