1-1-11
11
Single-Type
1-1. Unit Specifications
Ducted Type S-71PE1R5B / U-71PZ2R5
INDOOR MODEL
S–71PE1R5B – –
PANEL MODEL
– – –
OUTDOOR MODEL
– U-71PZ2R5 –
Branch pipe MODEL
–
Performance test condition
ISO13253 / AS/NZS3823.1
Power supply
ø, Hz
1ø 50 Hz 1ø 50 Hz
V
– 230 V 240 V – 230 V 240 V Min Max
C
O
O
L
I
N
G
Capacity
kW
– 7.1 7.1 – – – 2.0 8.0
BTU/h
– 24200 24200 – – – 6800 27300
Current A
– 1.24 1.25 – 9.35 8.90 – –
Input power
W
– 275 290 – 1.955k 1.940k – –
TOTAL W
– – 2.230k 2.230k 540 2.790k
Annual consumption TOTAL kWh *
4
– – 1115 - – –
EER/ AEER/ STAR RATING TOTAL (W/W/-)
– – – –
3.18/3.10/-
3.18 3.70 2.87
Power factor %
– – – – 91 91 – –
Noise indoor
dB-A (H/M/L)
45/44/43 – – –
Power Level dB
62/61/60 – – –
Noise outdoor
dB-A (H/L)
– 49/– – –
Power Level dB
– 67/– – –
H
E
A
T
I
N
G
Capacity
kW
– 7.1 7.1 – – – 1.8 8.6
BTU/h
– 24200 24200 – – – 6100 29300
Current A
– 1.24 1.25 – 7.15 6.75 – –
Input power
W
– 275 290 – 1.475k 1.460k – –
TOTAL W
– – 1.750k 1.750k 470 2.870k
COP/ ACOP/ STAR RATING TOTAL (W/W/-)
– – – –
4.06/3.93/-
4.06 3.83 3.00
Power factor %
– – – – 90 90 – –
Noise indoor
dB-A (H/M/L)
45/44/43 – – –
Power Level dB
62/61/60 – – –
Noise outdoor
dB-A (H/L)
– 49/– – –
Power Level dB
– 67/– – –
EXTRA LOW TEMP
Total capacity(kW) / Input power(W) / COP
– –
Max Current (A) / Max Input power (W)
– 1.30/290 1.31/305 –
16.4/3.39k 16.4/3.54k
–
Starting current (A) / Comp output (W)
– – – –
9.35/2.0k 8.90/2.0k
–
Network Impedance (ΩMAX.)
– – –
Fan motor output (Indoor/Outdoor) W
155 60 –
Moisture removal volume L/h(Pt/h)
4.2 (8.8) – –
External static pressure Pa
100 (MIN10 – MAX150) – –
Indoor
Air ow
Cooling m
3
/min (ft
3
/min)
30/26/22 (1059/918/777) – – –
Heating m
3
/min (ft
3
/min)
30/26/22 (1059/918/777) – – –
Outdoor
Air ow
Cooling m
3
/min (ft
3
/min)
– 52
(1836)
– –
Heating m
3
/min (ft
3
/min)
– 45
(1589)
– –
Refrigerant type / amount
g
(oz)
– R32
1.45 k (51.1)
–
Product dimension
Height mm(inch)
360
(14–5/32)
695 (27–23/64) –
Width mm(inch)
1100(+100)
(43–5/16(+3–15/16))
875 (34–29/64) –
Depth mm(inch)
700
(27–9/16)
320 (12–19/32) –
Packing dimension
Height mm(inch)
445
(17-33/64)
761 (29-61/64) –
Width mm(inch)
1315
(51-49/64)
1049 (41-19/64) –
Depth mm(inch)
812
(31-31/32)
460 (18-7/64) –
Weight
(NET) k
g
(lb)
42
(93) 44 (97)
–
(GROSS) k
g
(lb)
50
(110) 49 (108)
–
Layers limit (actually)
6(7) 3(4) –
Operation condition
Cool (DBT) 18˚C – 32˚C -10˚C – 43˚C
–
Heat (DBT) 16˚C – 30˚C -15˚C – 24˚C
–
MAX WORKING PRESSURE HP/LP MPa (bar) 4.15/2.55 (41.5/25.5)
–
P
I
P
I
N
G
Pipe diameter mm (inch)
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8) (Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
–
Connecting method, Standard length m(ft)
ared type, 5.0(16.4) ared type, 5.0(16.4) –
Pipe length range m (ft)
3 ~ 40m (9.8 ~131.2)
–
Indoor unit & Outdoor unit height difference m (ft)
15m(OD located lower)/30m(OD located higher) (49.2/98.4)
–
Add gas amount
g
/m (oz/ft)
35
g
/m (0.376)
–
Pipe length for additional gas m (ft)
30m (98.4)
–
*1 In case it is necessary to indicate the air flow volume in (l/s), the value in (m³/min.) shall be multiplied by 16.7 and rounded down the decimal point.
*2 If the EUROVENT Certified models can be operated under the "extra-low"temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage
230V shall be used.
*3 Network Impedance shall be applicable for EUROPE and CHINA models.
*4 The annual consumption is calculated by multiplying the input power at 230V(400V) by an average of 500 hours per year in cooling mode.
*5 EER and COP classification is at 230V(400V) only in accordance with EU directive 2002/31/EC.