1-1-24
11
Single-Type
1-1. Unit Specifications
Ceiling Type S-140PT2E5B / U-140PZ2R5
INDOOR MODEL
S-140PT2E5B – –
PANEL MODEL
– – –
OUTDOOR MODEL
– U-140PZ2R5 –
Branch pipe MODEL
–
Performance test condition
ISO5151 / AS/NZS3823.1
Power supply
ø, Hz
1ø 50 Hz 1ø 50 Hz
V
– 230 V 240 V – 230 V 240 V Min Max
C
O
O
L
I
N
G
Capacity
kW
– 13.6 13.6 – – – 3.3 15.0
BTU/h
– 46400 46400 – – – 11300 51200
Current A
– 0.91 0.88 – 19.4 18.6 – –
Input power
W
– 120 120 – 4.200k 4.200k – –
TOTAL W
– – 4.320k 4.320k 620 5.500k
Annual consumption TOTAL kWh *
4
– – 2160 – – –
EER/ AEER/ STAR RATING TOTAL (W/W/-)
– – – –
3.15/3.10/1.5
3.15 5.32 2.73
Power factor %
– – – – 94 94 – –
Noise indoor
dB-A (H/M/L)
47/41/37 – – –
Power Level dB
65/59/55 – – –
Noise outdoor
dB-A (H/L)
– 56/– – –
Power Level dB
– 71/– – –
H
E
A
T
I
N
G
Capacity
kW
– 14.0 14.0 – – – 3.4 16.0
BTU/h
– 47800 47800 – – – 11600 54600
Current A
– 0.91 0.88 – 16.9 16.2 – –
Input power
W
– 120 120 – 3.660k 3.660k – –
TOTAL W
– – 3.780k 3.780k 620 5.200k
COP/ ACOP/ STAR RATING TOTAL (W/W/-)
– – – –
3.70/3.64/2.5
3.70 5.48 3.08
Power factor %
– – – – 94 94 – –
Noise indoor
dB-A (H/M/L)
47/41/37 – – –
Power Level dB
65/59/55 – – –
Noise outdoor
dB-A (H/L)
– 56/– – –
Power Level dB
– 71/– – –
EXTRA LOW TEMP
Total capacity(kW) / Input power(W) / COP
– –
Max Current (A) / Max Input power (W)
–
0.91/120 0.88/120
– 30.0/6500 30.0/6800 –
Starting current (A) / Comp output (W)
– – – –
19.4/3.00k 18.6/3.00k
–
Network Impedance (ΩMAX.)
– – –
Fan motor output (Indoor/Outdoor) W
111 120 –
Moisture removal volume L/h(Pt/h)
9.0 (18.9) – –
External static pressure Pa
– – –
Indoor
Air ow
Cooling m
3
/min (ft
3
/min)
35/29/25
(1236/1024/883)
– – –
Heating m
3
/min (ft
3
/min)
35/29/25
(1236/1024/883)
– – –
Outdoor
Air ow
Cooling m
3
/min (ft
3
/min)
– 89.0 (3143) – –
Heating m
3
/min (ft
3
/min)
– 83.0 (2931) – –
Refrigerant type / amount
g
(oz)
– R32 2.98 k (105.1) –
Product dimension
Height mm(inch) 235 (9-1/4) 996 (39- 7/32)
–
Width mm(inch) 1590 (62-19/32) 980 (38-37/64)
–
Depth mm(inch) 690 (27-5/32) 370 (14- 9/16)
–
Packing dimension
Height mm(inch) 360 (14-11/64) 1134 (44-41/64)
–
Width mm(inch) 1655 (65-5/32) 1095 (43-7/64)
–
Depth mm(inch) 820 (32-9/32) 529 (20-53/64)
–
Weight
(NET) k
g
(lb)
40 (88) 94 (207) –
(GROSS) k
g
(lb)
49 (108) 102 (224) –
Layers limit (actually)
9 (10) 2 (3) –
Operation condition
Cool (DBT) 18˚C – 32˚C -10˚C – 43˚C
–
Heat (DBT) 16˚C – 30˚C -15˚C – 24˚C
–
MAX WORKING PRESSURE HP/LP MPa (bar) 4.15/2.55 (41.5/25.5)
–
P
I
P
I
N
G
Pipe diameter mm (inch)
(Liquid)
ø
9.52(3/8) (Gas)
ø
15.88(5/8) (Liquid)
ø
9.52(3/8) (Gas)
ø
15.88(5/8)
–
Connecting method, Standard length m(ft)
ared type, 5.0(16.4) ared type, 5.0(16.4) –
Pipe length range m (ft)
5 – 50m (16.4 – 164.0) –
Indoor unit & Outdoor unit height difference m (ft)
15m(OD located lower)/30m(OD located higher) (49.2/98.4) –
Add gas amount
g
/m (oz/ft)
45
g
/m
(0.484) –
Pipe length for additional gas m (ft)
30m (98.4) –
*1 In case it is necessary to indicate the air flow volume in (l/s), the value in (m³/min.) shall be multiplied by 16.7 and rounded down the decimal point.
*2 If the EUROVENT Certified models can be operated under the "extra-low"temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage
230V shall be used.
*3 Network Impedance shall be applicable for EUROPE and CHINA models.
*4 The annual consumption is calculated by multiplying the input power at 230V(400V) by an average of 500 hours per year in cooling mode.
*5 EER and COP classification is at 230V(400V) only in accordance with EU directive 2002/31/EC.
SM830266-00_大洋州向けR32シングルTD&SM.indb 24 18/03/29 10:19:25