1-1-23
11
Single-Type
1-1. Unit Specifications
Ceiling Type S-125PT2E5B / U-125PZ2R8
INDOOR MODEL
S-125PT2E5B – –
PANEL MODEL
– – –
OUTDOOR MODEL
– U-125PZ2R8 –
Branch pipe MODEL
–
Performance test condition
ISO5151 / AS/NZS3823.1
Power supply
ø, Hz
1ø 50 Hz 3ø 50 Hz
V
– 230 V 240 V – 400 V 415 V Min Max
C
O
O
L
I
N
G
Capacity
kW
– 12.5 12.5 – – – 3.2 13.5
BTU/h
– 42700 42700 – – – 10900 46100
Current A
– 0.86 0.83 – 5.60 5.40 – –
Input power
W
– 110 110 – 3.650k 3.650k – –
TOTAL W
– – 3.760k 3.760k 600 4.880k
Annual consumption TOTAL kWh *
4
– – 1880 – – –
EER/ AEER/ STAR RATING TOTAL (W/W/-)
– – – –
3.32/3.27/2.0
3.32 5.33 2.77
Power factor %
– – – – 94 94 – –
Noise indoor
dB-A (H/M/L)
46/40/36 – – –
Power Level dB
64/58/54 – – –
Noise outdoor
dB-A (H/L)
– 55/– – –
Power Level dB
– 70/– – –
H
E
A
T
I
N
G
Capacity
kW
– 12.5 12.5 – – – 3.3 15.0
BTU/h
– 42700 42700 – – – 11300 51200
Current A
– 0.86 0.83 – 4.75 4.60 – –
Input power
W
– 110 110 – 3.100k 3.100k – –
TOTAL W
– – 3.210k 3.210k 600 4.400k
COP/ ACOP/ STAR RATING TOTAL (W/W/-)
– – – –
3.89/3.82/-
3.89 5.50 3.41
Power factor %
– – – – 94 94 – –
Noise indoor
dB-A (H/M/L)
46/40/36 – – –
Power Level dB
64/58/54 – – –
Noise outdoor
dB-A (H/L)
– 55/– – –
Power Level dB
– 70/– – –
EXTRA LOW TEMP
Total capacity(kW) / Input power(W) / COP
– –
Max Current (A) / Max Input power (W)
–
0.86/110 0.83/110
– 10.0/6500 10.0/6750 –
Starting current (A) / Comp output (W)
– – – –
5.60/2.80k 5.40/2.80k
–
Network Impedance (ΩMAX.)
– – –
Fan motor output (Indoor/Outdoor) W
111 120 –
Moisture removal volume L/h(Pt/h)
7.9 (16.6) – –
External static pressure Pa
– – –
Indoor
Air ow
Cooling m
3
/min (ft
3
/min)
34/28/24 (1201/989/848) – – –
Heating m
3
/min (ft
3
/min)
34/28/24 (1201/989/848) – – –
Outdoor
Air ow
Cooling m
3
/min (ft
3
/min)
– 86.0 (3037) – –
Heating m
3
/min (ft
3
/min)
– 78.0 (2754) – –
Refrigerant type / amount
g
(oz)
– R32
2.98 k (105.1)
–
Product dimension
Height mm(inch) 235 (9-1/4) 996 (39- 7/32)
–
Width mm(inch) 1590 (62-19/32) 980 (38-37/64)
–
Depth mm(inch) 690 (27-5/32) 370 (14- 9/16)
–
Packing dimension
Height mm(inch) 360 (14-11/64) 1134 (44-41/64)
–
Width mm(inch) 1655 (65-5/32) 1095 (43-7/64)
–
Depth mm(inch) 820 (32-9/32) 529 (20-53/64)
–
Weight
(NET) k
g
(lb)
40 (88) 94 (207) –
(GROSS) k
g
(lb)
49 (108) 102 (224) –
Layers limit (actually)
9 (10) 2 (3) –
Operation condition
Cool (DBT) 18˚C – 32˚C -10˚C – 43˚C
–
Heat (DBT) 16˚C – 30˚C -15˚C – 24˚C
–
MAX WORKING PRESSURE HP/LP MPa (bar) 4.15/2.55 (41.5/25.5)
–
P
I
P
I
N
G
Pipe diameter mm (inch)
(Liquid)
ø
9.52(3/8) (Gas)
ø
15.88(5/8) (Liquid)
ø
9.52(3/8) (Gas)
ø
15.88(5/8)
–
Connecting method, Standard length m(ft)
ared type, 5.0(16.4) ared type, 5.0(16.4) –
Pipe length range m (ft)
5 – 50m (16.4 – 164.0) –
Indoor unit & Outdoor unit height difference m (ft)
15m(OD located lower)/30m(OD located higher) (49.2/98.4) –
Add gas amount
g
/m (oz/ft)
45
g
/m
(0.484) –
Pipe length for additional gas m (ft)
30m (98.4) –
*1 In case it is necessary to indicate the air flow volume in (l/s), the value in (m³/min.) shall be multiplied by 16.7 and rounded down the decimal point.
*2 If the EUROVENT Certified models can be operated under the "extra-low"temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage
230V shall be used.
*3 Network Impedance shall be applicable for EUROPE and CHINA models.
*4 The annual consumption is calculated by multiplying the input power at 230V(400V) by an average of 500 hours per year in cooling mode.
*5 EER and COP classification is at 230V(400V) only in accordance with EU directive 2002/31/EC.
SM830266-00_大洋州向けR32シングルTD&SM.indb 23 18/03/29 10:19:24