1-1-28
11
Single-Type
1-1. Unit Specifications
Low Silhouette Ducted Type S-100PF1E5B / U-100PZ2R5
INDOOR MODEL S–100PF1E5B
PANEL MODEL
OUTDOOR MODEL U-100PZ2R5
Branch pipe MODEL
Performance test condition ISO13253 / AS/NZS3823.1
Power supply
ø, Hz 1ø 50 Hz 1ø 50 Hz
V 230V 240V 230V 240V Min Max
C
O
O
L
I
N
G
Capacity
kW 10.0 10.0 3.0 11.5
BTU/h 34100 34100 10200 39200
Current A 1.30 1.27 11.6 11.1
Input power
W 195 195 2.535k 2.535k
TOTAL W 2.730k 2.730k 560 4.090k
Annual consumption TOTAL kWh *
4
1365
EER/ AEER/ STAR RATING TOTAL (W/W/-)
3.66/3.58/-
3.66 5.36 2.81
Power factor % 95 95
Noise indoor
dB-A (H/M/L) 38/34/31
Power Level dB 60/56/53
Noise outdoor
dB-A (H/L) 52/–
Power Level dB 68/–
H
E
A
T
I
N
G
Capacity
kW 10.0 10.0 3.0 14.0
BTU/h 34100 34100 10200 47800
Current A 1.34 1.29 9.70 9.30
Input power
W 200 200 2.120k 2.120k
TOTAL W 2.320k 2.320k 560 3.990k
COP/ ACOP/ STAR RATING TOTAL (W/W/-)
4.31/4.19/-
4.31 5.36 3.51
Power factor % 95 95
Noise indoor
dB-A (H/M/L) 38/34/31
Power Level dB 60/56/53
Noise outdoor
dB-A (H/L) 52/–
Power Level dB 67/–
EXTRA LOW TEMP
Total capacity(kW) / Input power(W) / COP
Max Current (A) / Max Input power (W) 1.75/265 1.70/265
25.0/5.50k 25.0/5.70k
Starting current (A) / Comp output (W)
11.6/2.50k 11.1/2.50k
Network Impedance (ΩMAX.)
Fan motor output (Indoor/Outdoor) W 235 120
Moisture removal volume L/h(Pt/h) 6.0 (12.6)
External static pressure Pa 100 (MIN10 – MAX150)
Indoor
Air ow
Cooling m
3
/min (ft
3
/min) 32/26/21
(1130 / 918 / 742)
Heating m
3
/min (ft
3
/min) 32/26/21
(1130 / 918 / 742)
Outdoor
Air ow
Cooling m
3
/min (ft
3
/min) 77.0 (2719)
Heating m
3
/min (ft
3
/min) 70.0 (2472)
Refrigerant type / amount
g
(oz) R32 2.60k (91.7)
Product dimension
Height mm(inch) 290 (11–13/32) 996 (39- 7/32)
Width mm(inch) 1400 (55–1/8) 980 (38-37/64)
Depth mm(inch) 700 (27–9/16) 370 (14- 9/16)
Packing dimension
Height mm(inch) 355 (13-31/32) 1134 (44-41/64)
Width mm(inch) 1614 (63-9/16) 1095 (43-7/64)
Depth mm(inch) 850 (33-15/32) 529 (20-53/64)
Weight
(NET) k
g
(lb) 45 (99) 90 (199)
(GROSS) k
g
(lb) 54 (119) 98 (216)
Layers limit (actually) 9 (10) 2 (3)
Operation condition
Cool (DBT) 18
°C
– 32
°C
-10
°
C – 43
°
C
Heat (DBT) 16
°C
– 30
°C
-15
°
C
– 24
°
C
MAX WORKING PRESSURE HP/LP MPa (bar) 4.15/2.55 (41.5/25.5)
P
I
P
I
N
G
Pipe diameter mm (inch)
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
(Liquid)Ø9.52(3/8) (Gas)Ø15.88(5/8)
Connecting method, Standard length m(ft) ared type, 5.0(16.4) ared type, 5.0(16.4)
Pipe length range m (ft) 5 – 50m (16.4 – 164.0)
Indoor unit & Outdoor unit height difference m (ft) 15m(OD located lower)/30m(OD located higher) (49.2/98.4)
Add gas amount
g
/m (oz/ft) 45
g
/m (0.484)
Pipe length for additional gas m (ft) 30m (98.4)
*1 In case it is necessary to indicate the air flow volume in (l/s), the value in (m³/min.) shall be multiplied by 16.7 and rounded down the decimal point.
*2 If the EUROVENT Certified models can be operated under the "extra-low"temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage
230V shall be used.
*3 Network Impedance shall be applicable for EUROPE and CHINA models.
*4 The annual consumption is calculated by multiplying the input power at 230V(400V) by an average of 500 hours per year in cooling mode.
*5 EER and COP classification is at 230V(400V) only in accordance with EU directive 2002/31/EC.
SM830266-00_大洋州向けR32シングルTD&SM.indb 28 18/03/29 10:19:25