1
1-264
TC :Heating Capacity
IPT :Heating Power Consumption
unit : kW
Model
Power
Source
Ambient
Return
Air
DB TC IPT TC IPT TC IPT TC IPT TC IPT
16 6.4 1.78 6.6 1.79 7.6 1.78 7.7 1.70 7.7 1.59
20 6.1 1.83 6.3 1.84 7.0 1.81 7.0 1.72 7.0 1.61
24 5.8 1.88 5.9 1.90 6.3 1.84 6.3 1.75 6.3 1.64
16 7.3 1.98 7.5 2.00 8.6 1.97 8.8 1.84 8.8 1.70
20 7.0 2.04 7.2 2.06 8.0 2.00 8.0 1.87 8.0 1.72
24 6.6 2.10 6.8 2.12 7.2 2.04 7.2 1.91 7.2 1.76
16 11.6 2.85 11.6 2.72 11.6 2.50 11.6 2.31 11.6 1.83
20 11.2 2.95 11.2 2.82 11.2 2.60 11.2 2.42 11.1 1.94
24 10.7 3.06 10.7 2.93 10.8 2.70 10.8 2.52 10.7 2.04
16 13.9 3.59 14.4 3.49 14.6 3.36 14.6 3.06 14.5 2.38
20 13.3 3.73 13.9 3.63 14.0 3.50 14.0 3.20 13.9 2.52
24 12.8 3.87 13.3 3.77 13.4 3.64 13.4 3.34 13.4 2.66
16 16.7 4.25 16.7 4.23 16.6 4.16 16.6 3.62 16.6 2.98
20 16.0 4.42 16.0 4.41 16.0 4.33 16.0 3.79 15.9 3.16
24 15.4 4.59 15.4 4.58 15.4 4.50 15.4 3.96 15.3 3.33
S-71PU1E5
U-71PE1E5
230V
240V
50Hz
1phase
230V
240V
50Hz
1phase
S-140PU1E5
U-140PE1E5
(U-140PE1E8)
230V
240V
50Hz
1phase
(3 phase)
S-100PU1E5
U-100PE1E5
(U-100PE1E8)
230V
240V
50Hz
1phase
(3 phase)
S-125PU1E5
U-125PE1E5
(U-125PE1E8)
230V
240V
50Hz
1phase
(3 phase)
15
S-60PU1E5
U-60PE1E5
Outdoor air intake temp(㷄䇭W.B.
-5 0 6 10
Combination of Single Unit
2. Heating Capacity Performance Data
4-Way Cassette Type
1-12. Capacity Table
SM830211-02PAC-i.indb264SM830211-02PAC-i.indb264 2012/07/1713:57:142012/07/1713:57:14