29
TC-L37DT30 Power On Operation
When the power button of the TV or remote control is pressed, The MPU (IC8000) of the A
board outputs the TV_SUB_ON command to turn on the transistors Q2001 and Q2002 which
provide STB5V to the photo-coupler located on the power supply board. The STB5V enters the
power supply board via pin 9 of connector P2. The TV_SUB_ON command is also connected
directly to the power supply to turn on a transistor that provides a ground connection to the
photo-coupler. When the photo-coupler turns on, the switched mode supply goes in operation to
create the +16V or and DC24V supplies.
On the A-Board, the +16V is regulated to numerous voltages to power the A-Board, LCD Panel,
and T-CON board.
The DC24V is applied to the LD-Board to power the circuit that controls the light output of the
backlight LEDs.
Caution: The A and P boards in the unit are to be exchanged only. The “Tcon/LED drive board”
is part of the LCD panel. If defective, the panel should be replaced.