27
8.22. Remove the C5-Board
1. Remove the Fan. (See section 8.9.)
2. Remove the Hanger metal R. (See section 8.15.)
3. Remove the Cabinet mount metal top. (See section 8.16.)
4. Disconnect the flexible cable holder fastening screws (×6
).
5. Disconnect the flexible cables (CA5, CA6, CA7 and CA8).
6. Disconnect the flexible cables (C50, C51 and C56).
7. Remove the screws (×4 ) and remove the C5-Board.
8.23. Remove the C6-Board
1. Remove the Hanger metal L. (See section 8.15.)
2. Remove the Cabinet mount metal top. (See section 8.16.)
3. Disconnect the flexible cable holder fastening screws
(×10 ).
4. Disconnect the flexible cables (CA9, CA10, CA11, CA12,
CA13, CA14 and CA15).
5. Disconnect the flexible cables (C61 and C66).
6. Remove the connector (C65).
7. Remove the screws (×4 ) and remove the C6-Board.
8.24. Remove the Plasma panel sec-
tion from the Cabinet assy
1. Remove the Cabinet mount metals fastening screws (×9
).
2. Remove the plasma panel fastening screws (×4 , ×8
) and remove the cabinet assy.
3. For leaving the cabinet assy from the plasma panel, pull