11.4. ABL adjustment
Instrument Name Connection Remarks
1. HD signal emitter (Color bar signal)
2. Wattmeter
COMPONENT input terminal
Connect the AC power of the
adjustment set to the wattmeter.
Procedure Remarks
·
Make sure the set is aged for 30 minutes or more before adjustment. (Do not switch off
during or after aging.)
·
Voltage 230V 50Hz (variation within 1%)
·
Volume at minimum and screen size at "16:9"
Setting
Component input, dynamic, standard
1. Connect the set´s AC power to the wattmeter.
2. Input the color bar.
3. Select the "APL MULT" item in the Serivice1.
4. Adjust APL MULT so the set´s power consumption is
TH-42PA50E 309 ± 10W
TH-42PE50B 317 ± 10W
TH-37PA50E 239 ± 10W
TH-37PE50B 247 ± 10W
1. The initial data are
0x25 for 37/42SD (A0-0626)
0x1E for 37HD (A0-0426)
0x24 for 42HD (A0-0826)
0x1D for 50HD (A0-0A26)
2. The power and data are in reverse relationship
(Lower the data to raise the power.)
·
Raising direction ():20 ® 1F
·
Lowering direction (¯):20 ® 1A
():20 ® 1F
(¯):20 ® 1A
According to the line condition,100V can be
used