Appendix
Heating capacity in relation to supply water and outside temperature
Aquarea T-CAP
Outside temperature Supply water temperature Models
30 35 40 45 50 55 9 kW (single phase)
WH-MXF09D3E5
WH-MXC09D3E5
-15 9.0 9.2 9.0 9.0 9.0 9.0
-7 9.0 9.0 9.0 9.0 9.0 9.6
2 9.0 9.2 9.0 9.0 9.0 9.0
7 9.0 9.3 9.0 9.2 9.0 9.1
25 13.6 13.6 13.2 12.8 12.0 11.2
30 35 40 45 50 55 12 kW (single phase)
WH-MXF12D6E5
WH-MXC12D6E5
-15 12.0 12.1 11.5 11.0 10.7 10.5
-7 12.0 11.6 12.0 12.0 12.0 9.0
2 12.0 11.8 12.0 12.0 12.0 12.0
7 12.0 12.1 12.0 12.5 12.0 12.7
25 13.6 13.6 13.4 13.2 12.6 12.0
30 35 40 45 50 55 9 kW (three phase)
WH-MXF09D3E8
WH-MXC09D3E8
-15 9.0 9.0 9.0 9.0 9.0 9.0
-7 9.0 9.0 9.0 9.0 9.0 9.0
2 9.0 9.0 9.0 9.0 9.0 9.0
7 9.0 9.0 9.0 9.0 9.0 9.0
25 13.6 13.6 13.2 12.8 12.0 11.2
30 35 40 45 50 55 12 kW (three phase)
WH-MXF12D9E8
WH-MXC12D9E8
-15 12.0 12.0 11.5 11.0 10.7 10.5
-7 12.0 12.0 12.0 12.0 12.0 12.0
2 12.0 12.0 12.0 12.0 12.0 12.0
7 12.0 12.0 12.0 12.0 12.0 12.0
25 13.6 13.6 13.4 13.2 12.6 12.0
Heating capacity [kW] of individual models of the monobloc system for different supply water and outside temperatures [°C].