EasyManua.ls Logo

Panasonic WH-SXC09H3E8 User Manual

Panasonic WH-SXC09H3E8
108 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Nederlands Italiano Español English
Operating Instructions
Air-to-Water Heatpump
Model No.
Indoor Unit Outdoor Unit
WH-SDC03H3E5-1
WH-SDC05H3E5-1
WH-SDC07H3E5-1
WH-SDC09H3E5-1
WH-UD03HE5-1
WH-UD05HE5-1
WH-UD07HE5-1
WH-UD09HE5-1
WH-SDC12H6E5
WH-SDC16H6E5
WH-UD12HE5
WH-UD16HE5
WH-SDC09H3E8
WH-SDC12H9E8
WH-SDC16H9E8
WH-UD09HE8
WH-UD12HE8
WH-UD16HE8
WH-SQC09H3E8
WH-SQC12H9E8
WH-SQC16H9E8
WH-UQ09HE8
WH-UQ12HE8
WH-UQ16HE8
WH-SXC09H3E5
WH-SXC12H6E5
WH-UX09HE5
WH-UX12HE5
WH-SXC09H3E8
WH-SXC12H9E8
WH-SXC16H9E8
WH-UX09HE8
WH-UX12HE8
WH-UX16HE8
Operating Instructions
Air-to-Water Heatpump
2-27
Thank you for purchasing Panasonic
product.
Before operating the system, please read these
operating instructions thoroughly and keep them for
future reference.
Installation Instructions attached.
Instrucciones de funcionamiento
Bomba de calor Aire-Agua
28-53
Gracias por comprar un producto
Panasonic.
Antes de utilizar la unidad, sírvase leer
atentamente estas instrucciones de funcionamiento
y conservarlas para futuras consultas.
Instrucciones de instalación adjuntas.
Istruzioni operative
Pompa di calore Aria-acqua
54-79
Grazie per aver acquistato un prodotto
Panasonic.
Prima di utilizzare l’unità, leggere attentamente le
istruzioni e conservare questo opuscolo per potervi
fare riferimento in futuro.
Istruzioni per l’installazione allegate.
Gebruiksaanwijzing
Air-to-Water Warmtepomp
80-105
Hartelijk dank voor het aanschaffen van
een Panasonic-product.
Lees voor u het apparaat gebruikt deze
gebruikshandleiding grondig en bewaar deze voor
toekomstig gebruik.
De instructies voor installatie zijn bijgevoegd.
ACXF55-21971
Manufactured by:
Panasonic AVC Networks Czech, s.r.o.
U Panasoniku 1, 320 84 Plzeň , Czech Republic

Table of Contents

Other manuals for Panasonic WH-SXC09H3E8

Questions and Answers:

Panasonic WH-SXC09H3E8 Specifications

General IconGeneral
TypeAir-to-Water Heat Pump
Heating Capacity9.00 kW
Cooling Capacity7.00 kW
Energy Efficiency Class (Heating)A+++
Energy Efficiency Class (Cooling)A++
RefrigerantR32
COP5.00
Operating Temperature Range (Heating)-20°C to +35°C

Summary

Operating Instructions Air-to-Water Heatpump

System Overview

Operating Conditions

Safety Precautions

Unit Safety Warnings

Covers safety instructions for indoor and outdoor units, including general warnings.

Safety Symbol Compliance

Explains symbols denoting prohibited actions and mandatory safety steps.

Power Supply Safety

Details crucial safety measures related to the unit's power supply and electrical connections.

Remote Controller Safety

Provides safety instructions specifically for the operation and handling of the remote controller.

Remote Controller Interface

Button and Indicator Identification

Identifies and explains the function of each button and indicator on the remote controller.

Display Icons and Modes

Explains the various icons and operational modes displayed on the remote controller screen.

Initial Setup Procedures

Language Selection

Instructions on how to select the preferred display language for the system.

Clock and Date Configuration

Procedure for setting the current date and time on the system.

Quick Menu Functions

Function Setup

Weekly Timer Configuration

Instructions for setting up weekly operational schedules for the system.

Holiday Timer

Sets a period to conserve energy by turning the system OFF or lowering temperature.

Quiet Timer

Allows setting a period for quiet operation of the system.

Room Heater Control

Enables or disables the room heater.

Tank Heater Control

Enables or disables the tank heater.

Sterilization Function

Controls the automatic sterilization feature for hot water.

System Check

Energy Monitor

Displays historical or present energy consumption and COP data.

Water Temperatures

Shows current water temperatures in various zones and tanks.

Error History

Displays a log of past system errors and allows clearing the history.

Compressor Performance

Shows compressor operating parameters like frequency and ON time.

Heater Operation Time

Displays total ON time for room and tank heaters.

Personal Setup

Touch Sound and Display Settings

Adjusts audible feedback, LCD contrast, and screen brightness.

Clock Format Selection

Sets the display format for the clock (12-hour or 24-hour).

Date and Time Configuration

Procedure for setting the current date and time accurately.

Language Selection

Allows changing the system's display language.

Unlock Password Setup

Sets or changes the password required to access system settings.

Service Contact

Contact 1 / Contact 2 Information

Stores contact details for authorized service personnel.

Installer Setup: System Configuration

Optional PCB Connectivity

Enables advanced functions via external PCB connection for servicing.

Zone and Sensor Configuration

Selects system zones and associated temperature sensors.

Heater Capacity Settings

Adjusts the heater power output to reduce unnecessary consumption.

Anti-Freezing Protection

Activates or deactivates freeze prevention for the system when OFF.

Tank Connection Setup

Establishes a connection between the system and the water tank.

Buffer Tank Connection

Connects the buffer tank to the system and sets its temperature.

Tank Heater Operation Settings

Configures the external or internal tank heater and its timer.

Base Pan Heater Configuration

Enables or configures the base pan heater for de-icing operations.

Alternative Outdoor Sensor

Allows selection of an alternative sensor for outdoor temperature readings.

Bivalent Connection Setup

Sets up an auxiliary heat source like a boiler for enhanced heating.

Bivalent Connection Control Strategies

Defines control patterns for bivalent heat sources, managing temperature and delay times.

External Switch Configuration

Sets up external switch inputs for system control.

Solar Connection Setup

Configures the solar connection for heating, including temperature settings.

External Error Signal

Configures external error inputs.

Demand Control Settings

Configures demand control functionalities.

SG Ready Configuration

Sets the system's SG Ready status.

External Compressor SW

Manages the external compressor switch.

Circulation Liquid Selection

Selects the circulation fluid (water or glycol).

Heat-Cool Switch

Enables or disables the heat-cool mode.

Force Heater Operation

Configures manual or automatic operation of the force heater.

Installer Setup: Operation Modes

Heat Mode Configuration

Sets water and ambient temperatures for optimal heating performance.

Cool Mode Configuration

Sets water and ambient temperatures for cooling operations.

Auto Mode Configuration

Configures automatic switching between heating and cooling modes.

Tank Operation Configuration

Sets functions related to the hot water tank, including operation time and re-heat temperature.

Installer Setup: Service Functions

Sterilization Function Settings

Configures the sterilization cycle, including day, time, and boiling temperature.

Pump Operation Settings

Manages pump speed and initiates pump down operation for maintenance.

Dry Concrete Mode

Utilizes the system for drying concrete during construction phases.

Service Contact Management

Enters and manages contact information for service technicians.

Cleaning and Maintenance Procedures

Indoor Unit Cleaning

Instructions for gently cleaning the indoor unit with a soft dry cloth.

Outdoor Unit Cleaning

Guidelines for clearing obstructions and snow from the outdoor unit's vents.

Water Filter Maintenance

Specifies the frequency and importance of cleaning the water filter.

Periodic Inspection Points

Highlights essential inspection points for optimal system performance.

Troubleshooting Common Issues

Symptom and Cause Analysis

Lists common symptoms and their potential causes for system issues.

Pre-Service Checks and Indicators

Outlines checks to perform before calling for service, including operational indicators.

System Error Code Reference

Provides a comprehensive list of error codes and their explanations.

System Information and Disposal

Network Adaptor Information

Details information regarding the optional network adaptor and its use.

Old Equipment Disposal Guidelines

Provides instructions for the collection and disposal of used electrical equipment.

Related product manuals