Aquarea air / water heat pump – design handbook 07 / 2014
Products, functions and technical data
Monobloc system
Technical data
Monobloc system
Series
Aquarea LT
Aquarea LT Aquarea T-CAP Aquarea HT
three phase single phase three phase single phase three phase
Monobloc unit
Model
WH-MDC05F3E5*
WH-MDF06E3E5*
WH-MDF09E3E5*
WH-MDF09C3E5
WH-MDC09C3E5
WH-MDF12C6E5
WH-MDC12C6E5
WH-MDF14C6E5
WH-MDC14C6E5
WH-MDF16C6E5
WH-MDC16C6E5
WH-MDF09C3E8
WH-MDC09C3E8
WH-MDF12C9E8
WH-MDC12C9E8
WH-MDF14C9E8
WH-MDC14C9E8
WH-MDF16C9E8
WH-MDC16C9E8
WH-MXF09D3E5
WH-MXC09D3E5
WH-MXF12D6E5
WH-MXC12D6E5
WH-MXF09D3E8
WH-MXC09D3E8
WH-MXF12D9E8
WH-MXC12D9E8
WH-MHF09D3E5
WH-MHF12D6E5
WH-MHF09D3E8
WH-MHF12D9E8
Output capacity
Heating capacity A-15 / W35 kW 4.87 5.93 7.57 8.11 8.74 9.66 9.67
7.99 8.93 9.77 10.14 9.23 12.06 9.0 12.0 9.0 12.0 9.0 12.0
Power consumption A-15 / W35 kW 1.98 2.53 3.6 3.29 3.78 4.23 4.38
3.17 3.56 3.93 4.24 3.73 5.24 3.54 5.0 3.75 5.57 3.75 5.58
Coefcient of performance A-15 / W35 – 2.46 2.34 2.1 2.47 2.31 2.28 2.21
2.52 2.51 2.48 2.39 2.5 2.32 2.54 2.4 2.4 2.15 2.4 2.15
Heating capacity A-7 / W35 kW 5.08 5.6 7.93 9.05 11.02 11.87 11.63
9.13 11.06 11.8 11.35 9.03 11.63 9.0 12.0 9.0 12.0 9.0 12.0
Power consumption A-7 / W35 kW 1.50 1.99 3.49 3.17 3.9 4.34 4.37
3.04 3.65 4.04 4.11 3.15 4.51 3.2 4.44 3.33 4.8 3.33 4.8
Coefcient of performance A-7 / W35 – 3.38 2.8 2.27 2.85 2.82 2.74 2.66
3.01 3.03 2.92 2.67 2.91 2.6 2.81 2.7 2.7 2.5 2.7 2.5
Heating capacity A2 / W35 kW 4.75 / 3.31
2
5.23 7.51 8.85 11.88 12.66 12.83
9.01 11.92 12.68 12.65 9.22 11.76 9 12 9 12 9 12
Power consumption A2 / W35 kW 1.23 / 0.81
2
1.48 2.38 2.47 3.45 3.90 3.96
2.40 3.33 3.65 3.78 2.52 3.54 2.55 3.53 2.65 3.61 2.65 3.61
Coefcient of performance A2 / W35 – 3.88 / 4.07
2
3.54 3.15 3.58 3.44 3.25 3.24
3.75 3.58 3.47 3.35 3.66 3.32 3.53 3.4 3.4 3.32 3.4 3.32
Heating capacity A7 / W35 kW 4.91 6.37 9.05 8.9 11.8 13.83 15.79
9.16 12.17 14.13 15.78 9.33 12.08 9 12 9.0 12.0 9.0 12
Power consumption A7 / W35 kW 0.95 1.33 2.11 1.81 2.68 3.27 3.81
1.82 2.6 3.15 3.73 1.96 2.6 1.9 2.57 1.98 2.73 1.98 2.73
Coefcient of performance A7 / W35 – 5.17 4.8 4.29 4.91 4.4 4.23 4.14
5.03 4.68 4.49 4.23 4.89 4.73 4.74 4.67 4.55 4.4 4.55 4.4
Heating capacity A2 / W55 kW 3.40 5.0 7.0 8.8 9.1 9.5 9.8
8.8 9.1 9.5 9.8 9.0 12.0 9.0 12.0 9.0 10.8 9.0 10.8
Power consumption A2 / W55 kW 1.64 2.5 3.88 3.98 4.18 4.4 4.55
3.98 4.18 4.4 4.55 4.11 5.51 4.11 5.51 3.92 4.9 3.91 4.91
Coefcient of performance A2 / W55 – 2.07 2.0 1.8 2.21 2.18 2.16 2.15
2.21 2.18 2.16 2.15 2.19 2.18 2.19 2.18 2.3 2.2 2.3 2.2
Cooling capacity A35 / W7 kW 4.50 – – 6.97 – 10.0 – 11.5 –
11.93
– 7.2 – 10.0 – 11.5 – 12.4 – 7.0 – 10.0 – 7.0 – 10.0 – – – –
Power consumption A35 / W7 kW 1.35 – – 2.25 – 3.6 – 4.4 – 4.8
– 2.25 – 3.6 – 4.4 – 4.8 – 2.25 – 3.6 – 2.25 – 3.6 – – – –
Coefcient of performance (EER) A35 / W7 – 3.33 – – 3.15 – 2.78 – 2.61 – 2.51
– 3.33 – 2.78 – 2.61 – 2.67 – 3.11 – 2.78 – 3.11 – 2.78 – – – –
Acoustics
Sound pressure level
1
dB(A) 47 47 49 49 50 51 53
49 50 51 53 49 50 49 50 49 50 49 50
Sound power level dB(A)
A7/W35: 62
3
A7/W45: 62
3
A7/W55: 62
3
65 67 60 63 63 64
60 62 64 65 60 60 66 67 66 67 66 67
Fan speed, top (heating / cooling) U / min
580 / 700 580 640
490 / 540 510 / 600 540 / 630 580 / 630
490 / 540 510 / 600 540 / 630 580 / 630 490 / 540 510 / 600 490 / 540 510 / 600 490 520 490 520
Fan speed, bottom (heating / cooling) U / min 530 / 580 550 / 640 580 / 670 620 / 670
530 / 580 550 / 640 580 / 670 620 / 670 530 / 580 550 / 640 530 / 580 550 / 640 530 560 530 560
Air ow rate (heating / cooling) m³ / min 43.3 / 47.1 46.7 51.6 76.8 / 89.5 80 / 93.3 84 / 97.8 90 / 97.8
76.8 / 89.5 80 / 93.3 84 / 97.8 90 / 97.8 76.8 / 89.5 80 / 93.3 76.8 / 89.5 80 / 93.3 76.8 80 76.8 80
Unit data
Dimensions (H × W × D) mm
865 × 1.283 × 320
1.410 × 1.283 × 320
Water-side connection inch AG R 1 ¼
Pump – speed stepping 7 3
Pump – power consumption (max.) W 47 75 190
Volumetric ow rate of heating circuit for
A7 / W35 / 30
l / min 14.3 17.2 25.8 25.8 34.4 40.1 45.9
25.8 34.4 40.1 45.9 25.8 34.4 25.8 34.4 25.8 34.4 25.8 34.4
Minimum circulation l / min 10 19
10 19 10 19 10 19 10 19 10 19
Safety valve (open / closed) bar 3 / ≤ 1.86 3 / ≤ 2.65 1.9 / ≤ 1.83
Electric
Capacity of the additional electric heater kW 3 6
Power consumption (heating / cooling) kW 0.99 / 1.35 1.36 2.2 1.9 / 2.25 2.57 / 3.6 3.11 / 4.4 3.78 / 4.8
1.9 / 2.25 2.57 / 3.6 3.11 / 4.4 3.78 / 4.8 1.9 2.57 1.9 2.57 1.98 2.73 1.98 2.73
Operation and starting current (heating / cooling) A 6.1 6.2 10.1 8.7 / 10.2 11.6 / 16.1 14.1 / 19.7 17.1 / 21.5
2.9 / 3.4 3.9 / 5.3 4.7 / 6.6 5.7 / 7.2 8.8 10.4 11.9 16.7 2.9 3.9 9.5 13 9.5 12.8
Power supply 1 (current consumption) A 19.5 20.5 22.9 22.9 24 25 26
11.8 8.8 9.4 9.9 25 29 14.7 11.9 28.5 29 32.8 29
Power supply 1 (frequency / voltage) Hz / V 50 / 230
50 / 400 50 / 230 50 / 400 50 / 230 50 / 400
Power supply 2 (current consumption) A 13 26
Power supply 2 (frequency / voltage) Hz / V 50 / 230
50 / 230 50 / 230 50 / 230 50 / 230 50 / 230
Power supply 3 (current consumption) A – – – – 13 13 13
– 13 13 13 – 13 – 13 – 13 – 13
Power supply 3 (frequency / voltage) Hz / V – – – 50 / 230
– 50 / 400 – 50 / 230 – 50 / 400 – 50 / 230 – 50 / 400
Temp.-
ranges
Operating range (outside temperature) °C -20 to 35 / 16 to 43
-20 to 35 -20 to 35 -20 to 35
Operating range (supply water temp. (H / C) °C 25 to 55 / 5 to 20
22 to 55 / 5 to 20 25 to 65 25 to 65
Panasonic measurement data in accordance with EN 14511-2. The data is to be considered as guidance values and not as a performance guarantee
* Devices have a high efciency pump and full the criteria of the Ecodesign Directive valid from 2015 for energy-related products (ErP)
1
Measured value in 1 m distance and in 1.5 m height
2
According to EHPA test regulation > 60 %
3
Measured as per BS EN 12102