Aquarea air / water heat pump – design handbook 07 / 2014
Interactive selection of the required functions for the planned heating system
via the HPM tool under www.hpmtool.eu
230 V power supply
Seven output relays
Two 0 to 10 V inputs / outputs
Eight sensor inputs (PT1000)
Integrated backlit text display
Micro-USB interface (for uploads, servicing,
remote control, trend)
RS485 interface (for communication with
additional heat pumps)
RS485 interface (for external display)
External touch screen available
Numerous different external remote
controls available
2 mixed heating circuits
Screed heating program
Cascaded control (max. of 3 heat pumps) /
bivalent control
Automatic switching between heating and
cooling modes
Possibility of connection to a photovoltaic sys-
tem or an intelligent power grid (“Smart Grid”)
Night-time reduction
Energy management system
Trend
Solar operation
Preferential hot water heating
Web-based access to the controller
Available in 10 languages
Note With the Aquarea Heat Pump Manager (HPM), Panasonic offer an
additional closed-loop controller that can be optionally used instead of
the normal Aquarea heat pump closed-loop controller. The HPM has an
extended range of functions for special applications and is generally
very easy to operate. The unit replaces the Aquarea heat pump closed-
loop controller and can be ordered separately if required. More informa-
tion is provided in the HPM handbook.
Technical properties and functions of the HPM Aquarea Heat Pump Manager:
Closed-loop control
Extensions and external interfaces
Aquarea Heat Pump Manager