EasyManua.ls Logo

Panasonic YT-CAW503T Series

Panasonic YT-CAW503T Series
20 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation
OM1105050JE03
11
1.4 Connecting Water Hoses
Set the water hoses along the torch cable and welding
cable, bind them together with plastic ties.
Keep binding up to end of the FA arm.
After fixing the water hose, connect them to a water cooling
unit and check that the hoses and cables have no extra
tension with the robot motion.
Note
Connect the blue hose to supply water and the red hose
 to drain water. Connecting the wrong hose could
cause torch burnout.
Required cooling water flow rate:1.2L/min.
Recommended water cooling unit: Panasonic YX-
09KGC1
1.5 Inlet for Air Blow
This torch is provided with a hole for the air blow inlet at the
side of the air blow base. Refer to the following figure and
make a hole of 10 mm diameter in the air blow base cover,
and remove the sunk plug from the air blow base. Then
attach the attached elbow union instead.
Note
Spatter tube for air blow unit is customer supplied.
Bind
Bind
14 mm
Sunk plug
Make a hole of φ 10 mm.
Air blow base cover
Elbow union