GSM Reporting (EBUS Connection)
Reporting Options
SMS Messages for Backup
Additional Programming Options
SMS Language
List of SMS Commands
EN Certification
The following statements apply for EN 50131 and EN 50136
certification:
Mode of operation is pass-through
PCS265LTE must be installed and connected to an EN approved
Grade 3 control panel
Monitoring of the transmission network interface (Internet
connection): In case of network/interface failure, the device sends
a trouble message to the control panel which then displays it via
connected keypad(s)
Information Security is achieved by 256-bit encrypted, supervised
communication (AES validation number 986) which prevents
unauthorized reading or modification of messages
Substitution Security is achieved by Information Security (as stated
above), physical security (Tamper protection) and by a unique
Serial Number from each device. Messages sent to the receiving
station include the S/N in order to identify the substitution and alert
accordingly
Technical Specifications
Safety Note: This device may operate continuously in temperature of
55°C (131°F) for a maximum period of 7 days.
Receiver Settings MG/SP
Receiver #:
IP address*
IP port **
IP address
WAN 2
IP port WAN2
Receiver password
Security Profile
1
[929]
[930]
[931]
[932]
[933]
[934]
2
[936]
[937]
[938]
[939]
[940]
[941]
Backup
[943]
[944]
[945]
[946]
[947]
[948]
Module registration - Press
[ARM] to register
[935] [942] [949]
Receiver Settings EVO
Receiver #:
IP address*
IP port **
IP address
WAN 2
IP port WAN2
Receiver password
Security Profile
1
[2984]
2
[2986]
3
[2988]
4
[2990]
* For 1 or 2 digit numbers, add “0’s” before the digit: e.g.,
138.002.043.006
** Default = 10000
Enter [MEM] for blank space
MG/SP EVO Details
[805] [2950] [1] Off + [2] Off = landline only (default)
[1] Off + [2] On = landline primary / GSM
backup (default)
[1] On + [2] Off = GSM primary / landline
backup
[1] On + [2] On = GSM only
[815] to
[817]
[3071] to
[3074]
Telephone numbers
[811] to
[812]
[3061] to
[3068]
Account numbers
Command Description
P[PASSWORD].SMS[GSM MODEM
TELEPHONE #].[IPRS-7 PASSWORD]
Used to program the
receiver’s SMS parameters
Language Value Language Value
English (default) 000 Bulgarian 016
French 001 Romanian 017
Spanish 002 Slovak 018
Italian 003 Chinese 019
Swedish 004 Serbian 020
Polish 005 Malay 021
Portuguese 006 Slovenian 022
German 007 Lithuanian 023
Turkish 008 Finnish 024
Hungarian 009 Estonian 025
Czech 010 French Canadian 026
Dutch 011 Belgian 027
Croatian 012 Latvian 028
Greek 013 Albanian 029
Hebrew 014 Macedonian 030
Russian 015
Command Description
P[password].A[IP
address].P[port number]
Used for LTE/4G/3G/2G remote
access
P[password].IP.[call back
phone number]
Used to obtain the IP address and IP
port of the PCS265 LTE and whether
or not the “bandwidth saver” option is
being used
P[password].RESET Used to reset the PCS265 LTE
P[password].BWS.ON Used to enable bandwidth saver
mode
P[password].BWS.OFF Used to disable bandwidth saver
mode
P[password].VOLOUT.[GSM
output volume]
Used to set the GSM output
volume; values range between 50 to
100
P[password].STATUS.[phone
number]
Used to obtain the signal strength,
signal quality, LTE/4G/3G/2G
connection status, and APN
settings of the current SIM card
P[password].APN1.NAME.
[AccessPoint Name]
Used to program the SIM Card 1
APN
P[password].
APN1.USER.[Access
Point Name]
Used to program the SIM card 1 APN
User Name
P[password].
APN1.PSW.[Access
Point Name]
Used to program the SIM card 1 APN
Password
P[password].APN1.CLEAR] Used to clear the SIM Card 1 APN
P[password].
VAPN1.NAME.[Access
Point Name]
Used to view the SIM card 1 APN
P[password].APN2.NAME.
[AccessPoint Name]
Used to program the SIM card 2 APN
P[password].
APN2.USER.[Access
Point Name]
Used to program the SIM card 2 APN
User Name
P[password].
APN2.PSW.[Access
Point Name]
Used to program the SIM card 2 APN
Password
P[password].APN2.CLEAR Used to clear the SIM card 2 APN
P[password].VAPN2.[CALL
BACK PHONE NUMBER]
Used to view the SIM card 2 APN
information
P[password].[IP1W1/ IP1W2/
IP2W1/ IP2W2/ IP3W1/
IP3W2/
IP4W1/ IP4W2].[domain name]
Set domain name for LTE/4G/3G/2G
receiver
P[password].[IP1W1/ IP1W2/
IP2W1/ IP2W2/ IP3W1/
IP3W2/IP4W1/ IP4W2]
.CLEAR
Clear domain name for LTE/4G/3G/
2G receiver
P[password].DNS.[ip address] Set domain name server (DNS) IP
address
P[password].DNS.CLEAR Clear domain name server (DNS) IP
address
P[password].VIP.[phone
number]
Get domain name server (DNS) info
Language Value Language Value
C[user code].[ARM/
OFF].A[area
number], [area number], [area
number]TO[area number]
Arm/Disarm
P{password].---S Disable SWAN polling
(V4.10.011 and higher)
P[password].+++S Enable SWAN polling
(V4.10.011 and higher)
Specifications Description
RF Power Class 4 (2W) @ 850/1900 MHz
Class 2 (1W) @ 1800/1900 MHz
UMTS 850/1900 @ 0.25W
(America)
UMTS 900/2100 @ 0.25W (Europe)
Antenna Bandwidth 5 bands, wideband
Voltage Input 12 VDC nominal
Consumption during
GPRS/GSM transmission
60mA standby
300 mA maximum
Encryption 128-bit (AES)
SMS Protocol 7-bit (GSM: 3GPP TS 23.038/
GSM03.38)
or 16-bit (UCS2 ISO/IEC10646)
SIM Cards LTE/4G/3G
GSM (2G - n/a for North and South
America)
Humidity 0 - 90% non-condensing
Operating Temperature -20 - 50 °C (-4 to 122 °F)
Dimensions 20.8 x 7.5 x 2 cm / 8.2 x 2.9 x 0.8 in.
Certifications EN 50136-1 EN 50136-2 Grade 3
Class II
EN 50131-10 ATS Category SP5
Certification Body: Applica Test and
Certification
Command Description
Warranty
The Limited Warranty Statement can be found on the website www.paradox.com/terms.
Patents
Your use of the Paradox product signifies your acceptance of these terms and
conditions. The following US patents may apply 5,886,632 and 6,215,399. Other
Canadian and international patents may apply.
©2019 Paradox Security Systems (Bahamas) Ltd. All rights reserved. Specifications
may change witho.ut prior notice.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox PCS265 LTE and is the answer not in the manual?

Paradox PCS265 LTE Specifications

General IconGeneral
BrandParadox
ModelPCS265 LTE
CategoryControl Unit
LanguageEnglish

Related product manuals