Magellan & Spectra SP • Programming Guide
Appendix A
EN 50131 Programming
The following sections describe all the programming required for your panel to be EN 50131 compliant (MG5050 version 4.96 or higher).
NOTE: The Installer Quick Menu is not available anymore for MG5050 V4.96 or higher.
To set your panel to be EN 50131 compliant:
1. Enter section [951] to unlock the software and set EN 50131 defaults.
2. Press Enter.
NOTE: All keypads in the system must have anti-tamper enabled in order to be EN 50131 compliant.
EN 50131 Standard System Defaults
The following sections are provide the system defaults that will be set for EN50131 compliancy. The following provides information on sections [700] through
[840].
ATZ Options
Table 58: Description of section [700]
Section Option Option Type Description OFF ON
Section [700]
1 Partitioning Partitioning Disabled
Enabled
2
General system options
Battery charging (not for MG5075) 350mA
700mA
3 Audible trouble warning (except AC failure) Disabled
Enabled
4 Audible trouble warning on AC failure Disabled
Enabled
5 RF jamming supervision RF jamming supervision
Disabled Enabled
6
General system options
Exit delay termination Disabled
Enabled
7 Tamper supervision on the bus module
Disabled Enabled
8 Panel Tamper Panel Tamper Supervision
Disabled Enabled
Table 59: Description of section [703]
Section Option Option Type Description OFF ON
Section [703]
1
Keypad options 2
One-touch regular arming (also REM3) Disabled
Enabled
2 One-touch stay arming (also REM3) Disabled
Enabled
3 One-touch sleep arming (also REM3) Disabled
Enabled
4 One-touch bypass programming Disabled
Enabled
5
Arming/disarming options
Restrict arming on battery failure
Disabled
Enabled
6
Restrict arming on tamper failure (zone + bus
module + wireless PGM)
Disabled
Enabled
7
Restrict arming on supervision trouble;
wireless zones & PGM + bus module
Disabled
Enabled
8 Arm/disarm with VDMP3 Arm/disarm with VDMP3
Disabled Enabled
Table 60: Description of section [705]
Option Description OFF ON
Section [705]
1 ATZ zone doubling Disabled
Enabled
2ATZ wiring options Series
Parallel
3
Tamper recognition (see following table)
Disabled Enabled
4 Disabled
Enabled
5 Generate tamper on bypassed zone
No Ye s
6
Supervision options (see following table)
Disabled Enabled
7 Disabled
Enabled
8 Generate supervision on bypassed zone
No Ye s
= Default

Table of Contents

Other manuals for Paradox SP6000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox SP6000 and is the answer not in the manual?

Paradox SP6000 Specifications

General IconGeneral
Partitions2
User Codes32
Event Buffer256 events
PGM Outputs2 (expandable to 16)
CompatibilityCompatible with wireless expansion modules and keypads
CommunicationPhone line, GSM, IP
Users32
ZonesUp to 32 (5 on-board)
KeypadsSupports multiple keypad types

Related product manuals