Magellan & Spectra SP • Programming Guide
7
Zones
Delays
Time and Date
Walk Test Mode
Installer and Maintenance Codes
BabyWare
Monitoring Phone Number
Step Action Details
1
+ installer code
= flash; programmed zones are lit (buttons
or LED, depending on keypad); maintenance
code may also be used
2 Zone number Two digits: 01 to 32
3 Enroll or erase zone
Wireless zone: open/close cover or press
LEARN/TAMPER switch; for 2WPGM remove and
re-install Jumper 2 (JP2)
hardwired zone: press
ENTER;
to erase a programmed zone, press and hold
SLEEP for three seconds
4Zone type
See Zone Definitions on page 16, for the zone
type
5
Assign partition
(1 and/or 2 +
ENTER)
If applicable, assign the zone to one or both
partitions, and then press
ENTER; by default, all
zones are assigned to partition 1
NOTE: If applicable, partition 2 status LEDs display signal strength of selected
wireless zone (4 LEDs = best signal; 1 LED = weak signal; no LEDs = hardwired
panel/keypad zone).
Step Action Details
1
+ installer code
= flash; maintenance code may also be
used
2 -
3
1 = entry delay 1 Default: 045 sec.
2 = entry delay 2 Default: 045 sec.
3 = exit delay Default: 060 sec.
4 = bell cut-off Default: 004 min.
4 000 to 255
Entry/exit delay = seconds;
bell cut-off = minutes
Step Action Details
1
+ installer code
= flash; maintenance code may also be
used
2
+ 5 -
3 Time (HH:MM) If HH = 13 or more, go to step 5
4Time format 1 = 24 hr. format, 2 = AM, 3 = PM
5 Date (YYYY/MM/DD) Enter the year/month/day
NOTE: For SP4000 and SP65 systems, the time format must be entered in 24
hr. format, therefore, omit step 4.
Step Action Details
1
+ installer code
= flash; maintenance code may also be
used
2 -
3 6 Activates or deactivates walk test mode
Step Action Details
1
+ installer code
= flash
2 -
3
7 for installer
code
8 for
maintenance
code
-
4 Code Enter a four or six-digit code
5 Confirm code Re-enter the four or six-digit code, to confirm
NOTE: To erase a code, press and hold
SLEEP for three seconds.
Step Action Details
1
+ installer code
= flash
2 -
3 9 -
4 Phone # +
ENTER
Enter PC phone number (up to 32 digits), and
then press
ENTER
5 Panel ID Enter four-digit panel ID
6 PC password Enter four-digit PC password
NOTE: To erase the BabyWare phone number, panel ID, and PC password,
press and hold
SLEEP for three seconds.
Step Action Details
1
+ installer code
= flash
2-
3 1 -
4 Phone # +
ENTER
Enter monitoring station phone number (up
to 32 digits), and then press
ENTER
5 Partition 1 account # -
6
1 for CID
2 for SIA
SIA is not supported with GPRS/IP reporting
7 Partition 2 account # -
NOTE: To erase monitoring phone number, reporting format, and account
numbers, press and hold
SLEEP for three seconds.
Installer Quick Menu

Table of Contents