Magellan & Spectra SP • Programming Guide
43
Event Call Direction Options
GSM Options
IP/GPRS Options
Table 38: Description of event call direction options (sections [802] to [804])
Option Description OFF ON Option Description OFF ON
Section [802]
Event Call Direction Options 1
1
Call tel. #1/monitoring rcvr. #1 for
arm/disarm report codes
Disabled Enabled
Section [803]
Event Call Direction Options 2
1
Call tel. #1/monitoring rcvr. #1 for
tamper/restore report codes
Disabled Enabled
2
Call tel. #2/monitoring rcvr. #2 for
arm/disarm report codes
Disabled Enabled 2
Call tel. #2/monitoring rcvr. #2 for
tamper/restore report codes
Disabled Enabled
3N/A 3N/A
5
Call tel. #1/monitoring rcvr. #1 for
alarm/restore report codes
Disabled Enabled 5
Call tel. #1/monitoring rcvr. #1 for
trouble/restore report codes
Disabled Enabled
6
Call tel. #2/monitoring rcvr. #2 for
alarm/restore report codes
Disabled Enabled 6
Call tel. #2/monitoring rcvr. #2 for
trouble/restore report codes
Disabled Enabled
7N/A 7N/A
Section [804]
Event Call Direction Options 3
1
Call tel. #1/monitoring rcvr. #1 for
special report codes
Disabled Enabled
= Default
2
Call tel. #2/monitoring rcvr. #2 for
special report codes
Disabled Enabled
3N/A
5
Call personal tel. # on zone alarm
(burglary/fire)
Disabled Enabled
6 Call personal tel. # on panic alarms
Disabled Enabled
7
Call personal tel. # on paramedic
alarms
Disabled Enabled
8
Call personal tel. # on panel power
trouble
Disabled
Enabled
Table 39: Description of GSM options (PCS series)
Option Description OFF ON Option
Primary Backup
Option
Description
Section [805]
1 & 2 GSM reporting
See options 1
& 2, on right
See options 1
& 2, on right
12 56
3 & 4 Future use - - - - OFF OFF Landline Landline OFF OFF Disabled
5 & 6
GSM/GPRS no service trouble
feedback
See options 5
& 6, on right
See options 5
& 6, on right
OFF ON Landline GSM OFF ON Trouble only
7 Future use - - - - ON OFF GSM Landline ON OFF
When disarmed: trouble
only; when armed: audible
alarm
8 GSM RF jamming supervision
Disabled Enabled ON ON GSM GSM ON ON
Silent alarm becomes
audible alarm
= Default
Table 40: Description of IP/GPRS options (section [806])
Option Description OFF ON Option
Description
Section [806]
5 & 6 IP no service trouble feedback See options 5 & 6
See options 5 & 6 5 6
7User dialer reporting
As IP/GPRS
reporting backup
Enabled OFF OFF Disabled
8 Enable IP/GPRS reporting
Disabled Enabled OFF ON Trouble only
= Default
ON OFF
When disarmed: trouble only; when
armed: audible alarm
ON ON Silent alarm becomes audible alarm

Table of Contents

Other manuals for Paradox SP7000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox SP7000 and is the answer not in the manual?

Paradox SP7000 Specifications

General IconGeneral
Partitions2
Event Buffer256 events
Wireless Zones32
PGM Outputs2
CompatibilityParadox modules and accessories
CommunicationGSM, IP
System TypeHybrid
Power Supply16.5VAC
Backup Battery7Ah
Bus4-wire (Digiplex EVO)

Related product manuals