10 Complete Installation Manual
6.7 PANIC ALARMS
The panic alarm, if programmed, will immediately generate an alarm after pressing and holding the [1] and [3] keys for two seconds (see section
4.4) (disabled by default).
6.8 ALARM MEMORY DISPLAY
A record of the zones that were in alarm the last time the system was armed will be stored in memory. After disarming the system, press the
[
MEM] button to display the zones that were in alarm. To exit the Alarm Memory Display, press the [CLEAR] button. The control panel will erase the
contents of the alarm memory every time the system is armed.
Zone
[5] will illuminate if an alarm has occurred on the keypad zone or if the keypad’s on-board tamper was triggered (see section 2.10).
The control panel cannot distinguish the difference between the two. Zone
[8] will illuminate if the panic alarm keys (see section 4.4)
were pressed.
6.9 PROGRAMMING CHIME ZONES
Press and hold any key from [1] to [5] for 3 seconds to activate or deactivate Chiming for zones 1 to 6. For example, press and hold the [1] key
to enable chiming on zone 1. If after pressing and holding a key, the keypad emits a confirmation beep, the chime feature has been enabled for that
zone. If the keypad emits a rejection beep, the chime feature has been disabled for the corresponding zone.
6.10 KEYPAD MUTING
Press and hold the [CLEAR] button for 3 seconds to enable or disable keypad muting. When muted, the keypad will only beep when a key is
pressed and when the keypad emits a rejection or confirmation beep. All other beep functions are disabled.
7: PROGRAMMING GUIDE
To program the Spectra 1727 control panel, use a keypad to enter the Programming Mode as shown below.
USER CODES
Sections [02] to [09] can only be programmed by the System Master Code (see section 5.4).
Table 4: Pre-programmed Options for User Codes
Section User Codes
Can
Change Code
Can
Reg. Arm
Can
Disarm
Can
Bypass Arm
Can
Stay Arm
Can
Force Arm
[01] Installer Code
[02] Master Code

[03] User Code 01

[04] User Code 02

[05] User Code 03

[06] User Code 04

[07] User Code 05

[08] User Code 06

[09] User Code 07
DEFAULT INSTALLER CODE: 0000/000000
DEFAULT SYSTEM MASTER CODE: 1234/123400
How Do I Enter Programming Mode?
STEP 1: Press [ENTER]
STEP 2: Enter your [INSTALLER CODE] (default: 0000/000000) or [SYSTEM MASTER CODE] (default: 1234/123400)
STEP 3: Enter the 2-digit [SECTION] you wish to program
STEP 4: Enter the required [DATA]
Section #
[01] Installer Code
[ENTER] + [CURRENT INSTALLER CODE] + [01] + new 4- or 6-digit Installer Code

Other manuals for Paradox SPECTRA 1686H

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox SPECTRA 1686H and is the answer not in the manual?

Paradox SPECTRA 1686H Specifications

General IconGeneral
BrandParadox
ModelSPECTRA 1686H
CategoryControl Panel
LanguageEnglish

Related product manuals