Page 68 • BASIC Stamp II Manual 0.94 • Parallax, Inc. • (916) 624-8333
BASIC Stamp II
XOUT
Output X-10 powerline control codes to a PL513 or TW523 powerline
interface module.
usage: XOUT mpin,zpin,[house\keyorcommand{\cycles,...]
Mpin will be made a low output and is the modulation control.
Zpin will be made an input and is the zero-crossing detect.
House is the house code (0-15 is ‘A’-’P’).
Keyorcommand is a key (0-15 is ‘1’-’16') or command (see table below).
Cycles is an optional number which overrides the default of two; this
should only be used with ‘dim’ and ‘bright’ commands.
X-10 Command (symbol) Value
UNITON %10010
UNITOFF %11010
UNITSOFF %11100
LIGHTSON %10100
DIM %11110
BRIGHT %10110
The following chart gives the wiring connections for connecting the
Stamp II to a PL513 or TW523 powerline interface module.
Powerline Interface Pin Stamp II Pin
1 Zpin
2 GND
3 GND
4 Mpin
Application note #1 gives a good description of the X-10 system, as
well as how to use it with the Stamp II.